No. 51922
TM-H1700G
32
Item
Test equipment
Test points
Adjustment
locations
Adjustment procedure
V. Center
Adjustment
Signal generator
(Circle pattern)
D03 (V. CENTER)
[SERVICE MENU]
9. Input the PAL circle pattern signal.
10. Adjust D03 to agree with CRT center and signal
center of vertical direction.
V. Lin
Adjustment
Signal generator
(Circle pattern)
D04 (V. SIZE)
D05 (V. LIN)
D06 (V. S. COR)
[SERVICE MENU]
11. Input the PAL circle pattern signal.
12. Select the D04 to adjust the vertical size become
100%.
13. Select the D05 and reference to the below figure,
adjust it to become correctly about vertical size and
vertical linearity.
14. Select D06 and adjust it to the circle pattern
becomes the true circle at top and bottom of the
screen.
Top extension
Correct adjustment
Bottom extension
Horizontal extension
Correct adjustment
Vertical extension
Only for PAL
signal
adjustment
Only for PAL
signal
adjustment