No.51922
TM-H1700G
29
Item
Test equipment
Test points
Adjustment
locations
Adjustment procedure
PAL CHROMA
Saturation
adjustment
Signal generator
(Full colour bar)
Oscillo-scope
TP-47B
TP-E(
)
[CRT SOCKET
PWB]
S03(PAL CHROMA)
[SERVICE MENU]
1. Input a PAL full colour bar signal.
2. Connect the oscillo-scope probe to TP-47B and
TP-E(
).
3. Select the SIGNAL BLOCK mode from <BLOCK
SELECT> screen.
4. Select the S03 item.
5. Adjust the S03 to become the voltage different
between 75% white and blue to
0V
±
±
±
±
2Vp-p
as
shown in figure.
NTSC 3.58
CHROMA
Saturation
adjustment
Signal generator
(Full colour bar)
Oscillo-scope
TP-47B
TP-E(
)
[CRT SOCKET
PWB]
S04
(NTSC CHROMA)
[SERVICE MENU]
1. Input a NTSC 3.58 full colour bar signal.
2. Connect the oscillo-scope probe to TP-47B and
TP-E(
).
3. Select the SIGNAL BLOCK mode from <BLOCK
SELECT> screen.
4. Select the S04 item.
5. Adjust the S04 to become the voltage different
between 75% white and blue to
0V
±
±
±
±
2Vp-p
as
shown in figure.
BL
B
R
Mg
G
Cy
Y
W
75%
BL
B
R
Mg
G
Cy
Y
W
75%
0V
±±±±
2V
0V
±±±±
2V