10
SYSTEM
RM-P2580 System
System with up to 8 cameras
(Sixteen position settings available for each camera.)
• Confirm switch settings on the screen as follows.
q
Confirm that the image from the camera to be
checked is displayed on the monitor.
w
Turn OFF and then ON the AC 24 V power to the
camera to be checked.
e
The camera begins the initial operation and
characters similar to those shown in the illustration
on the right appear on the monitor screen.
r
Confirm that “DUPLEX” and “ID-
” are displayed
and that the ID number is the correct number (the
number should be the same as the number of the
VIDEO INPUT terminal to which the camera is
connected on the rear panel of the RM-P2580).
t
If wrong, set the camera ID again.
MONITOR screen
(example showing camera ID as “05”)
“DUPLEX” should
be displayed.
The number shown in
the
□□
part of ID-
□□
should be correct.
REC
PLAY
FF
REW
REVERSE
PAUSE/
STILL
REC
CHECK
STOP/EJECT
COUNT/
CLOCK
TIME
MODE
TIMER
REC
AL/PL
RESET
MENU
VIDEO CASSETTE RECORDER
SHIFT/TRACKING
SET/V.LOCK
RESET
/CANCEL
OPERATE
SR-L910
OPE. LOCK
1
TO CAMERA
DATA I / O
RX
RX+
+
RX
RX-
−
TX
TX+
+
TX
TX-
−
COM
COM
1
2
3
4
5
6
7
8
COM
COM 9/1 10/2 11/3 12/4 13/5 14/6 15/7 16/8
16/8 COM
COM
COM
COM
COM
COM
CAMERA
SW
UNIT
ALARM
ALARM
AUTO
AUTO
4
3
1 2
8
7
5 6
2
3
4
5
6
7
8
1
MONITOR
MONITOR
OUTPUT
OUTPUT
MONITOR
MONITOR
SERIAL-2
SERIAL-2
SERIAL-1
SERIAL-1
VIDEO INPUT
VIDEO INPUT
VIDEO OUTPUT
VIDEO OUTPUT
OUTPUT
OUTPUT
2
1
ON
ON
2
3
4
5
6
7
8
POWER
OFF
ON
AC INPUT
〜
I N
T I A L
I
P R O T
O
O
L
D U P L E X
I D - 0 5
C
Camera
TK-AM200
Camera
TK-AM200
Camera
TK-AM200
Camera 1
Camera 2
Camera 8
Camera ID: 01
Termination: OFF
Camera ID: 02
Termination: OFF
Camera ID: 08
Termination: ON
Control signal cable
Video signal cable
Power cable
Remote Control Unit
RM-P2580
Time lapse VCR
MONITOR
MONITOR
AC24V
AC24V
AC24V
CAM SW
OUT
VIDEO IN
COM
CAMERA
SW
TO
CAMERA
MONITOR
OUTPUT 2
MONITOR
OUTPUT 1
Memo:
• When operating a system using the RM-P2580, several cameras (up to 8) can be connected and
used on one control signal cable. Consequently, an incorrect switch setting on just a single camera
will cause the entire system to work incorrectly.
11
Connections
Settings
When connecting
●
Turn OFF the power supply to all equipment to be used before making connections.
●
Carefully read the Instruction Manual for each piece of equipment to be used before
making connections.
●
For the appropriate connection cables and the length of these, carefully read “Connections
to Camera Terminal Board” on page 12.
●
The control signal cable cannot be used for loop connection.
Lug plates
AC 24 V power cable
To AC 24V power
supply
To RM-P2580
To VIDEO INPUT
terminal on
RM-P2580
Connecting the control signal cable
(Use a twisted-pair cable for connection.
See page 13.)
Camera 2
terminal board
Connect:
Camera TX+ to RM-P2580 RX+
Camera TX– to RM-P2580 RX–
Camera RX+ to RM-P2580 TX+
Camera RX– to RM-P2580 TX–
The
A
B
C
D
marks indicated
on both the camera terminals
and the RM-P2580 terminals
facilitate correct connections.
Connect the terminals with
identical marks.
C
TX
+
D
TX
–
A
RX
+
B
RX
–
TX
+
A
TX
–
B
RX
+
C
RX
–
D
TX
+
A
TX
–
B
RX
+
C
RX
–
D
TX
+
A
TX
–
B
RX
+
C
RX
–
D
RM-P2580
Camera 1
terminal board
Camera 3
terminal board
Control
signal cable
Video signal cable
(coaxial cable)
Terminal board
RX+ C
RX– D
A TX+
B TX–
1 2 3 4
ON
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
Camera ID setting switches
Set to match the RM-P2580 VIDEO
INPUT terminal number for each
camera.
Switch 3: Set this to ON (signal termination ON) only
on the camera placed at the end of the
control signal cable.
Set to OFF on all other cameras.
Switch 2: Set to OFF (DUPLEX) side.
Switch 1: Set to ON (MULTIDROP) side.
Control signal selector switch:
Set to the RS-422A/RS-485 side.
(Example: Camera 1
ID “
×
10” position 0,
ID “
×
1” position 1)
Switch 4: Select the synchronization method of the
camera image.
Set the switch on all cameras to ON (Line
Lock) and match with the V. PHASE.
(Only possible in 60 Hz regions.)
(
See page 20.)