(No.YA011)1-37
SUB COLOUR(1)
Signal
generator
Remote
control unit
[2. V/C]
9. COLOUR
[Method of adjustment without measuring instruments]
PAL COLOUR
(1) Receive PAL broadcast.
(2) Select 2. V/C.
(3) Set the initial setting value for < 9. COLOUR >.
(4) If the colour is not the best with the initial set value,
make fine adjustment until you get the best colour.
(5) Press the [MENU] key and memorize the adjustment value.
SECAM COLOUR
(1) Receive SECAM broadcast.
(2) Select 2. V/C.
(3) Set the initial setting value for < 9. COLOUR >.
(4) If the colour is not the best with the initial set value,
make fine adjustment until you get the best colour.
(5) Press the [MENU] key and memorize the adjustment value.
NTSC 3.58 COLOUR
(1) Input NTSC 3.58MHz COMPOSITE VIDEO signal.
(2) Select 2. V/C.
(3) Set the initial setting value for < 9. COLOUR >.
(4) If the colour is not the best with the initial set value,
make fine adjustment until you get the best colour.
(5) Press the [MENU] key and memorize the adjustment value.
SUB COLOUR(2)
Signal
generator
Oscilloscope
Remote
control unit
TP-47R
TP-E
[CRT SOCKET
PWB]
[2. V/C]
9. COLOUR
[Method of adjustment using measuring instruments]
PAL COLOUR
(1) Receive PAL full field colour bar signal (75% white).
(2) Select 2. V/C.
(3) Set the initial setting value of < 9. COLOUR >.
(4) Connect the oscilloscope between TP-47R and
TP-E at the CRT SOCKET PWB.
(5) Adjust < 9. COLOUR > and bring the value of (A) in
the illustration to the values as shown in the table
(Voltage difference between white (W) and red (R)).
(6) Press the [MENU] key and memorize the adjustment value.
SECAM COLOUR
(1) Receive SECAM colour bar signal (75% white).
(2) Select 2. V/C.
(3) Set the initial setting value of < 9. COLOUR >.
(4) Connect the oscilloscope between TP-47R and
TP-E at the CRT SOCKET PWB.
(5) Adjust < 9. COLOUR > and bring the value of (A) in
the illustration to the values as shown in the table
(Voltage difference between white (W) and red (R)).
(6) Press the [MENU] key and memorize the adjustment value.
NTSC 3.58 COLOUR
(1) Input NTSC3.58MHz full field colour bar signal (75%
white).
(2) Select 2. V/C.
(3) Set the initial setting value for < 9. COLOUR >.
(4) Connect the oscilloscope between TP-47R and
TP-E at the CRT SOCKET PWB.
(5) Adjust < 9. COLOUR > and bring the value of (A) in
the illustration to the values as shown in the table
(Voltage difference between white (W) and red (R)).
(6) Press the [MENU] key and memorize the adjustment value.
Item
Measuring
instrument
Test point
Adjustment part
Description
Initial setting value
PAL
SECAM
NTSC 3.58
80
55
63
Colour system
(+)
(-)
0
(75%)
W
Y
Mg
B
R
G
Cy
(A)
Adjustment value
PAL
NTSC 3.58
SECAM
+5V
0V
-2V
Colour system