1-34 (No.YA011)
4.8.6
VSM PRESET
Item
Measuring
instrument
Test point
Adjustment part
Description
VSM
PRESET
setting
Remote
control unit
[5. VSM PRESET]
1. CONT
2. BRIGHT
3. SHARP
4. COLOUR
5. TINT
6. WDR R
7. WDR G
8. WDR B
(1) Select 5. VSM PRESET
(2) Set the PICTURE MODE to "BRIGHT".
(3) Select < 1. CONT >.
(4) Set the initial setting value of VSM PRESET, as
shown in the table given below.
(5) Press the [MENU] key to memorize the setting
value.
(6) Select < 2. BRIGHT > to < 8. WDR B > in turn. Check
and set the values.
(7) Respectively select the "STANDARD" to "WARM",
and make similar adjustment as same step as
avobe.
NOTE:
Refer to OPERATING INSTRUCTIONS to switch the
PICTURE MODE.
BRIGHT
CONT
BRIGHT
SHARP
COLOUR
TINT
WDR R
WDR G
WDR B
STANDARD
SOFT
COOL
NORMAL
PICTURE MODE
COLOUR TEMP
WARM
+16
+2
-8
-----
-----
-----
0
0
0
-----
-----
-----
0
0
-2
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
-----
0
0
-2
-----
-----
-----
0
0
0
-----
-----
-----
-6
0
+11
0
0
0
+12
0
0