53
Connection
䡵
When connecting external time code generator
to a master device
1
Input the external synchronizing signal to the external
time code generator and the [GENLOCK/AUX INPUT]
terminal of this camera recorder.
Make use of BB signal or HDTV
3
level synchronizing signal
as the external synchronizing signal.
Note :
●
If the power of the camera recorder is turned ON/OFF
during input of the external synchronizing signal, the
screen may be disrupted for a few seconds. This is not a
malfunction.
2
Input the SMTPE/EBU LTC time code from the
external time code generator to the [TC IN] terminal of
this camera recorder.
䡵
When connecting multiple units of this camera
recorder with one as the master and the rest as
slave devices
1
Connect the [TC OUT] terminal of the master device to
the [TC IN] terminal of the slave device.
2
Connect the [Y/VIDEO] terminal of the master device
to the [GENLOCK INPUT] terminal of the slave device.
Settings on the Camera Recorder
1
Set to the Camera mode. (
2
Set the [GENLOCK/AUX] selection switch to
A
GENLOCK
B
. (U model)
3
Set [Genlock Input] in the [Others] menu to
A
BNC
B
.
4
Set [TCG Source] in the [TC/UB] menu as follows.
●
Slave device
: Set to
A
External
B
●
Master device
: Set to
A
Internal
B
5
Set the LCD monitor or viewfinder as follows.
●
Viewfinder
: Set to the STATUS 1 screen display
●
LCD monitor
: Set to the enlarged status display
screen (
The input and synchronizing status of the external time
code generator are displayed as follows.
Camera Recorder Operation
1
Set the external time code generator or master device,
and run the time code.
●
When the built-in time code generator is synchronized
with the input of the external time code generator,
L
on
the STATUS 1 screen or enlarged status display screen
will light up.
●
If the time code is not synchronized or when there is no
time code input,
L
does not light up.
Memo :
●
After synchronization is complete, the built-in time code
generator will continue to run even when the external time
code generator or master device is disconnected.
●
The user’s bit becomes the data of the external time code
generator or master device.
SYNC Signal Generator
External Time Code
Generator
External Synchronizing Signal
[GENLOCK/AUX] Switch
[GENLOCK/AUX INPUT] Terminal (U Model)
[GENLOCK INPUT] Terminal (E Model)
External Synchronizing Signal
Master Device
Slave Device
LTC Time Code
To [TC IN]
terminal of
another camera
[GENLOCK/AUX INPUT] Terminal
Master Device
[TC IN] Terminal
Slave Device
[TC OUT] Terminal
[Y/VIDEO] Output Terminal
0 0 : 0 0 : 0 0 : 0 0
20 min
MAX 12
3
%
MIN 45%
SKIN AREA
S.DTL
B -
3
ND1/16 A<
3
200K>
F5.6 AE+1 9dB 1/10000
STBY
100min
100min
1280x720
60p HQ
OK
B
A
282min
3
0/24 fps
DD
DF
EXT
A
B 12
3
min
min
OK
1280 x 720
60p HQ
CH1
CH2
STBY
100min
67.8min
DD
[TCG Source] :
A
External
B
Status Screen
Enlarged Status Display Screen
Lights up
Lights up
0 0 : 0 0 : 0 0 : 0 0
20 min
MAX 12
3
%
MIN 45%
SKIN AREA
S.DTL
B -
3
ND1/16 A<
3
200K>
F5.6 AE+1 9dB 1/10000
STBY
100min
100min
1280x720
60p HQ
OK
B
A
282min
3
0/24 fps
DD
DF
EXT
A
B 12
3
min
min
OK
1280 x 720
60p HQ
CH1
CH2
STBY
100min
67.8min
DD
[TCG Source] :
A
External
B
Status Screen
Enlarged Status Display Screen
Lights up
Lights up
Summary of Contents for GY-HM790U
Page 5: ...V ...