23
<Functions controlled by the MAKE/TRIGGER system>
Display
Functions to be controlled
Opening
Short-circuiting
TALLY SEL
Selects the color of the tally lamp
Green
Red
SDI 1
Changes the input to “SDI 1”
Invalid
Valid
SDI 2
Changes the input to “SDI 2”
Invalid
Valid
DVI
Changes the input to “DVI”
Invalid
Valid
Display
Functions to be controlled
Invalid
Valid
COMPO.
Changes the input to “COMPO.”
Invalid
Valid
VIDEO
Changes the input to “VIDEO.”
Invalid
Valid
3G-B.DS
Selects the data stream of “3G SDI LEVEL B”
DS1
DS2
DUAL LINK
Turns on or off “SDI DUAL LINK”
Off
On
A.MARKER
The area marker indication
Off
On
S.MARKER
The safety marker indication
Off
On
FRAME
Indication of the area of the specified aspect ratio
Off
On
C.MARKER
The center marker indication
Off
On
MARK.SEL
Selects the items of “MARKER” *
3
Non-“R-” items
“R-” items
ASPECT
Changes the aspect ratio
4:3
16:9
1:1
Displays in 1:1 mode
Off
On
STATUS
Status display *
4
☞
“On the Status Display” on page 12
L.METER
Audio level meter display
*
5
TIME CODE
Time code display
Off
On
SOURCE ID
☞
“SOURCE ID” in “INFORMATION” on page 21
*
6
WAVE FORM
Displays the wave form monitor (Normal or Difference)
*
7
VECTOR
Displays the vector scope
COLOR OFF
Color off
Color
Monochrome
SCR CHECK
Screens check
*
8
I/P MODE
Change a mode according to the input picture
*
9
MUTING
Muting on/off
Off
On
DIMMER
Change the intensity of the button lamps
NORMAL
DARK
−−−
No function
—
—
*
3
Selects which functions in “MARKER” are activated, non-“R-” items or “R-” items (
☞
“MARKER” on page 15).
*
4
Displays the information shown when INPUT SELECT button of the current input is pressed (
☞
“On the Status Display” on page 12). While controlling
with the MAKE system, the information is displayed only at the moment of short-circuiting.
*
5
While controlling with the MAKE system, the level meter is switched between displayed (short-circuiting) and hidden (opening). When “LEVEL METER
ch” is set to “OFF,” the level meter is not displayed (“NO EFFECT” appears). While controlling with the TRIGGER system, the pattern of the audio
channel display is switched.
*
6
While controlling with the MAKE system, the available set-up options will be the setting value currently selected in “SOURCE ID” (“ON” or “AUTO”
[short-circuiting]) and “OFF” (opening). While controlling with the TRIGGER system, uses the same set-up option as those in the SET-UP MENU (
☞
“SOURCE ID” in “INFORMATION” on page 21).
*
7
While controlling with the MAKE system, the wave form monitor and vector scope is switched between displayed (short-circuting) and hidden
(opening) regardless of the “AUTO OFF” setting in the MAIN MANU. While controlling with the TRIGGER system, the screen is switched in the same
way as when pressing the SCOPE button (
☞
e
on page 10). If the wave form monitor and vector scope are input at the same time, the wave form
monitor is displayed.
*
8
While controlling with the MAKE system, the screen is switched between normal screen (opening) and blue screen (short-circuiting). While
controlling with the TRIGGER system, the screen changes in the same way as when pressing SCREENS CHECK button (
☞
q
on page 10).
*
9
Must be controlled with the TRIGGER system. The mode changes in the order of “NORMAL”
\
“CINEMA”
\
“FIELD” (This function cannot be
controlled with the MAKE system).
●
You cannot assign the same function to different pin terminals.
●
The TRIGGER system switches each function by short-circuiting the pin terminal for about 1 second and opening it.
DTV21G11̲LCT2681.indb 23
DTV21G11̲LCT2681.indb 23
12.2.5 10:17:11 AM
12.2.5 10:17:11 AM