(No.PA037<Rev.001>)1-23
5.3
ERROR LOG (SELF-DIAGONOSIS RECORD AND INDICATION)
5.3.1 Outline
By using the special setting and adjustment software, data related to abnormal operation (history) stored in the projector can be load.
On the basis of contents "LED (INDICATOR) WARNING INDICATONS" set and lamp use time, internal and external temperature,
and ther data prior to the previous usage time can be viewed as a table.
z
HOW TO LOAD THE DATA FROM UNIT
(1) Install the software in a personal computer and connect by
RS-232C IN terminal (use cross cable).
(2) Set the projector to stand-by mode.
(3) Start the setting and adjustment software.
(4) Click the [Read Log] button and save the TEXT file. Data
become the latest data so as to go below.
(5) The first number is error code.
(6) Click the [Clean Log] button and delete all data stored in
projector.
z
ERROR LOG SCREEN ITEMS
z
POWER STATUS
0: Stand-by mode
1: Power on mode
2: Cooling mode
4: Emergency mode
ERROR CODE
SETUP NUMBER
LAMP TIME(Min)
SYSTEM TIME(Min)
OUTSIDE TEMPERATURE
INSIDE TEMPERATURE
POWER STATUS
NOT USED
F1, 17, 568, 1840, 42, 44, 1, 00, 00
No.
Item
Detected condition
1 Error code 01:No projection caused by the lamp failure.
03:Error of IIC data.
06:Lamp extinction during the projection.
07:Ventilation fan in the unit is stopped.
[Fan Lock]
08:Internal temperature becomes extraordinar-
ily higher.
09:Exhaust temperature at the vent is extraor-
dinarily high or forced high due to high ambient
temperature.
15:The lamp cover is removed.
16:Error communication in DD CPU.
17:DD CPU is reset.
18:DD CPU malfunctions.
19: PROCESSOR PWB malfunctions.
1A: POWER PWB malfunctions.
1B: Lens barrier malfunctions.
20:Lamp did OFF by sleep time function.
F0:Just after POWER ON.
F1:Once a hour after POWER ON
F2:POWER OFF. (Included Emergency mode)