4 Command control
61 / 61
PJ04030102B
6
Additional Information for THX Adjustment
6.1
State Transition Diagram
Fig.6-1 State transition chart
・
<>: Remote Control code
・
【】
: RS232C Command
・
When power goes off during “Adjust(During Adjustment)”, State moves to “ON(After Adjustment)” automatically.
・
No Link with isf Adjustment.(isf Adjustment is possible regardless of THX Adjustment mode.)
6.2
Remote Control Code
Remote control code relating to THX adjustment is as follows.
Table 6-1
Remote Control code relating to THX
No Remote control code
Meaning
Comments
1
0x05
Power On
Power on when PJ is in stand-by state.
2
0x06
Power Off
Power off when PJ is in power-on state.
3
0xC6
THX Adjustment State
Move to THX Adjustment state.
4
0xC7
THX Off
Move to THX Off state (Factory default)
5
0xC8
THX On
Move to THX After Adjustment state
End of specification
①
THX: Off (Before Adjustment, Factory Default)
・
THX Selection: Not Possible
・
Adjustment: Not Possible
Power off state (Stand-by)
②
THX: Adjust (During Adjustment)
・
THX Selection: Possible
・
Adjustment: Possible
③
THX : ON (After Adjustment)
・
THX Selection: Possible
・
Adjustment: Possible
<0x05>
【
PW:1
】
Power on state
<0x06>
【
PW:0
】
<0xC6>
【
PMTH:2
】
<0xC8>
【
PMTH:1
】
<0xC7>
【
PMTH:0
】
<0xC7>
【
PMTH:0
】
<0xC8>
【
PMTH:1
】
<0xC6>
【
PMTH:2
】