1-33
CA-MXS6MDR
SP-MXS6MD
5.Independent operation mode
In case the checking mode or adjustment
when occur the error at disc adjustment,
Independent mode into by select the key
before release the TERST MODE.
Operation key
Remote controller [SLEEP]
Remote controller [6 key]
Remote controller [7 key]
Remote controller [8 key]
Remote controller [9 key]
Remote controller [STOP]
Main body [EJECT]
MODE
Focus search [FOCUS_SEARCH]
Pit rough servo [P.R.SERVO]
Groove rough servo [GR.R.SERVO]
Tracking ON [TRACKING_ON]
Tracking OFF [TRACKING_OFF]
STOP [STOP]
EJECT [EJECT]
Release the TEST MODE
MD TEST MODE 2
TEST MODE 2
Read the TOC
Press [6 key] of the
Remote controller
LCD indication
[ _ ]
Insert the Pre-master disc
2.Indication the drift level of
the pickup adjustment value
4.Release the MD TEST MODE
TEST MODE 2
Read the TOC
Press [8 key] of
the Remote controller
LCD indication (change by each 10sec.)
[_ _ _ _ _]
Insert the recordable
disc (basically 74min.)
LCD indication (change be each 10sec.)
[______ Times_]
3.Indication the C1 ERROR
Adjustment value
IVR
TAGC
TBAL
LPOW
FBIA
FAGC
TEOF
SAGC
IVR (Pre-master, Recordable groove)
TRK AGC ( )
TRK BALANCE ( ) = 0
Laser power (Play power=0 Rec power)
Focus bias ( ) = 0
Focus AGC ( )
TE offset ( ) = 0
Sled AGC ( )
TEST MODE
Press [POWER key]
POWER OFF
1.Setting the TEST MODE 2
Press [STOP key] and
[CANCEL key] together,
and connect the power cord.
LCD indication
MD TEST MODE 1
Setting the MD TEST MODE1
by press [POWER key]
LCD indication
[HELLO] then
[MD TEST MODE 1]
Setting OK
Setting the MD TEST MODE2
by press [STOP key] and
[TITLE/EDIT key] together
(CAUTION) MD mode should NO
DISC condition, when POWER
ON to not read TOC.