AV-N29304
AV-N29430
(No.52129)1-21
WHITE
BALANCE
(HIGH LIGHT)
Signal
generator
Remote
control unit
[8.HIGH LIGHT]
S14 : R DRIVE
S15 : B DRIVE
(1) Receive the black-and-white signal (color off).
(2) Select the 8.HIGH LIGHT in the SERVICE MENU.
(3) Set the initial setting value of <S14>(R DRIVE) and
<S15>(B DRIVE) with the [4], [6], [7] and [9] keys of
the remote control unit.
(4) Adjust the screen until it becomes white using the
[4], [6], [7] and [9] keys of the remote control unit.
The [3] EXIT key is the cancel key for the 8.HIGH
LIGHT mode.
SUB BRIGHT
Remote
control unit
[1.V/C(S)]
S01 : BRIGHT
(1) Receive the broadcast.
(2) Select <S01>(BRIGHT) of the 1.V/C(S).
(3) Set the initial setting value of the <S01> with the
[VOLUME (-/+)] key.
(4) If the brightness is not the best with the initial setting
value, make fine adjustment of the <S01> until you
get the optimum brightness.
SUB
CONTRAST
Remote
control unit
[1.V/C(S)]
S02 : PICTURE
(1) Receive the broadcast.
(2) Select <S02>(PICTURE) of the 1.V/C(S).
(3) Set the initial setting value of the <S02> with the
[VOLUME (-/+)] key.
(4) If the contrast is not the best with the initial setting
value, make fine adjustment of the <S02> until you
get the optimum contrast.
Item
Measuring
instrument
Test point
Adjustment part
Description
KEY ASSIGNMENT OF REMOTE CONTROL UNIT
R DRIVE
R DRIVE
EXIT
B DRIVE
B DRIVE
No.
S14
Setting item
R DRIVE
0
㨪
127
Variable
range
Initial setting
value
64
S15
G DRIVE
0
㨪
127
64
No.
S01
Setting item
BRIGHT
0
㨪
127
Variable
range
Initial setting
value
64
No.
S02
Setting item
PICTURE
0
㨪
127
65
Variable
range
Initial setting
value