No. 52084
AV-29BF11ENS
AV-29BF11EPS
AV-29BF11EES
20
Item
Measuring
instrument
Test point
Adjustment part
Description
VERTICAL
CORNER
CORRECTION
adjustment
(50Hz)
Signal
generator
Remote
control unit
VCCO
1. Receive a PAL B/G cross-hatch pattern signal of vertical
frequency 50Hz.
2. Enter
GEOMETRY
MENU.
3. Select VCCO (Vertical corner correction) with the FUNCTION
( / ) key.
4. Adjust VCCO with the FUNCTION ( / ) key until the vertical
length of the upper and lower part squares of the cross-hatch
pattern become equal to each other.
5. Check and readjust VCCO item if the adjustment becomes
improper after some other geometric adjustments are done.
HORIZONTAL
SIZE
adjustment
(50Hz)
Signal
generator
Remote
control unit
HSIZ
1. Receive a PAL B/G cross-hatch pattern signal of vertical
frequency 50Hz.
2. Enter
GEOMETRY
MENU.
3. Select HSIZ (Horizontal size) with the FUNCTION ( / ) key.
4. Adjust HSIZ with the FUNCTION ( / ) key until the vertical
black lines on both the left and right part of the cross-hatch
pattern become very close to the left and right horizontal sides
of picture tube and nearly about to disappear.
HORIZONTAL
POSITION
adjustment
(50Hz)
Signal
generator
Remote
control unit
HPOS
1. Receive a PAL B/G circle pattern signal of vertical frequency
50Hz.
2. Enter
GEOMETRY
MENU.
3. Select HPOS (Horizontal position) with the FUNCTION ( / )
key.
4. Adjust HPOS with the FUNCTION ( / ) key until the circle
pattern is horizontally centered.(
C
=
D
)
5. Check and readjust HPOS item if the adjustment becomes
improper after some other geometric adjustments are done.
Picture size 100%
Screen size
Very close
Very close
C
D