Item
Measuring
instruments
Test point
Adjustment part
Description
VERTICAL
POSITION
OFFSET
adjustment
(60Hz)
Signal
generator
Remote
control unit
VPOF
1. Receive a NTSC-M circle pattern of vertical frequency 60Hz.
2. Enter
SERVICE
MENU.
3. Select VPOF (Vertical position) with the FUNCTION ( / )
key.
4. Adjust VPOF with the FUNCTION ( / ) key until the
picture is vertically centered.(
C
=
D
)
5. Check and readjust vertical position item if the adjustment
becomes improper after some other geometric adjustments
are done.
HORIZONTAL
SIZE
OFFSET
adjustment
(60Hz)
Signal
generator
Remote
control unit
HSOF
1. Receive a NTSC-M cross-hatch pattern of vertical frequency
60Hz.
2. Enter
SERVICE
MENU.
3. Select HSOF (Horizontal size) with the FUNCTION ( / )
key.
4. Adjust HSOF with the FUNCTION ( / ) key until the
vertical black lines on both the left and right part of the
pattern become very close to the left and right vertical sides
of picture size and nearly about to disappear.
5. Check and readjust a HSOF item if the adjustment becomes
improper after some other geometric adjustments are done.
HORIZONTAL
POSITION
OFFSET
adjustment
(60Hz)
Signal
generator
Remote
control unit
HPOF
1. Receive a NTSC-M circle pattern signal of vertical frequency
60Hz.
2. Enter
SERVICE
MENU.
3. Select HPOF (Horizontal position) with the FUNCTION ( / )
key.
4. Adjust HPOF with the FUNCTION ( / ) key until the circle
pattern is horizontally centered.(
E
=
F
)
6. Check and readjust a horizontal position item if the adjustment
becomes improper after some other geometric adjustments
are done.
C
D
E
F
Picture size 100%
Screen size
Very close
Very close