(No.YA225)1-17
TRAPEZIUM
adjustment
Signal
generator
Remote
control unit
034
(REGULAR)
044
(PANORAMIC)
054
(14:9 ZOOM)
064
(16:9 ZOOM)
074
(16:9 ZOOM
SUBTITLE)
114
(FULL)
(1) Receive a PAL crosshatch signal.
(2) Enter the SERVICE MODE.
(3) Select ADJUST MENU.
(4) Select
034
(REGULAR).
(5) Adjust
034
until vertical lines, especially lines at the
sides of the picture frame become parallel to the
both sides of picture tubes as close as possible.
(6) Check and readjust
034
item if the adjustment
becomes improper after some other geometric
adjustments are done.
(7) Select
044
(PANORAMIC).
(8) Adjust
044
in the same procedure.
(9) Select
054
(14:9 ZOOM).
(10) Adjust
054
in the same procedure.
(11) Select
064
(16:9 ZOOM).
(12) Adjust
064
in the same procedure.
(13) Select
074
(16:9 ZOOM SUBTITLE).
(14) Adjust
074
in the same procedure.
(15) Select
114
(FULL).
(16) Adjust
114
in the same procedure.
SIDE PIN
adjustment
Signal
generator
Remote
control unit
035
(REGULAR)
045
(PANORAMIC)
055
(14:9 ZOOM)
065
(16:9 ZOOM)
075
(16:9 ZOOM
SUBTITLE)
115
(FULL)
(1) Receive a PAL crosshatch signal.
(2) Enter the SERVICE MODE.
(3) Select ADJUST MENU.
(4) Select
035
(REGULAR).
(5) Adjust
035
until vertical lines close to the both sides
of the picture frame become parallel to vertical sides
of picture tube without any bending to left or to right
side of the screen.
(6) Check and readjust
035
item if the adjustment
becomes improper after some other geometric
adjustments are done.
(7) Select
045
(PANORAMIC).
(8) Adjust
045
in the same procedure.
(9) Select
055
(14:9 ZOOM).
(10) Adjust
055
in the same procedure.
(11) Select
065
(16:9 ZOOM).
(12) Adjust
065
in the same procedure.
(13) Select
075
(16:9 ZOOM SUBTITLE).
(14) Adjust
075
in the same procedure.
(15) Select
115
(FULL).
(16) Adjust
115
in the same procedure.
Item
Measuring
instrument
Test point
Adjustment part
Description
Parallel
Parallel