1-16 (No.YA225)
HORIZONTAL
SIZE
adjustment
Signal
generator
Remote
control unit
039
(REGULAR)
049
(PANORAMIC)
059
(14:9 ZOOM)
069
(16:9 ZOOM)
079
(16:9 ZOOM
SUBTITLE)
119
(FULL)
(1) Receive a PAL crosshatch signal.
(2) Enter the SERVICE MODE.
(3) Select ADJUST MENU.
(4) Select
039
(REGULAR).
(5) Adjust
039
until vertical lines on both the left and
right part of the cross-hatch will be visible nor screen
will be so wide.
(6) Check and readjust
039
item if the adjustment
becomes improper after some other geometric
adjustments are done.
(7) Select
049
(PANORAMIC).
(8) Adjust
049
in the same procedure.
(9) Select
059
(14:9 ZOOM).
(10) Adjust
059
in the same procedure.
(11) Select
069
(16:9 ZOOM).
(12) Adjust
069
in the same procedure.
(13) Select
079
(16:9 ZOOM SUBTITLE).
(14) Adjust
079
in the same procedure.
(15) Select
119
(FULL).
(16) Adjust
119
in the same procedure.
ANGLE
adjustment
Signal
generator
Remote
control unit
016
(1) Receive a PAL crosshatch signal.
(2) Enter the SERVICE MODE.
(3) Select ADJUST MENU.
(4) Select
016
.
(5) Adjust
016
until the vertical lines of the crosshatch
pattern become straight.
(6) Check and readjust
016
item if the adjustment
becomes improper after some other geometric
adjustments are done.
BOW
adjustment
Signal
generator
Remote
control unit
017
(1) Receive a PAL crosshatch signal.
(2) Enter the SERVICE MODE.
(3) Select ADJUST MENU.
(4) Select
017
.
(5) Adjust
017
until the vertical lines become straight.
(6) Check and readjust
017
item if the adjustment
becomes improper after some other geometric
adjustments are done.
NOTE:
In case where there is a bow-shaped distortion of
images on the screen. (Figure)
Item
Measuring
instrument
Test point
Adjustment part
Description
Screen size
Very
close
Very
close
Picture size 100%