www.juwent.com.pl

80

HEATING AND VENTILATION UNITS

ВОЗДУШНО-ОТОПИТЕЛЬНЫЕ АГРЕГАТЫ

M damper actuators

Damper  Actuators  are  used  to  control  dampers  in  the  open  air 

circulation system. The actuators are designed for placing the damper 

in  the  required  position  and  for  protecting  the  water  heating  coils 

against  freezing.  Depending  on  the  damper  control  system  selected, 

the following actuators are available:

 

open/close „on-off”

 

continuous  operation:  0..10V.  In  the  latter  type,  the  desired 

damper position is obtained by applying control signal, ranging from 

0 to 10VDC, from the ZW damper position presetting unit.

Электропривод для воздушной заслонки М

Для  управления  воздушными  заслонками  наружного  воздуха 

применяются  электроприводы  (рис.11),  задачей  которых  является 

установление воздушной заслонки в необходимом положении, а также 

защита водяного воздухонагревателя от замерзания. В зависимости от 

способа управления используются два типа электроприводов:

 

типа откр./закр.; 

 

с  плавным  регулированием  (управляющий  сигнал  0…10B). 

Установка  заслонки  в  нужном  положении  осуществляется  при 

подаче управляющего напряжения 0…10В с позиционера ZW.

Fig. 16 M damper actuator

Рис. 16 Электропривод для воздушной заслонки M

Actuator type

Тип электропривода

on/off - NE1, NE2

откр/закр - NE1, NE2

constant signal, NE3, NE4

непрерывный сигнал, NE3, NE4

Supply voltage

Напряжение питания

230V AC

230В AC

24V AC

24В AC

Opening/closing time

Время закрытия/открытия

150 s

150 c

150 s

150 c

Protection level

Степень защиты

IP54

IP54

ZW damper position presetting unit

ZW damper Position Presetting Unit enables presetting of the damper 

in  any  desired  position  so  that  the  exact  required  air  flow  from  the 

outside is established. The ZW damper position presetting unit is placed 

inside of or on the door of the control box.

Позиционер ZW

Позиционер  позволяет  установить  воздушную  заслонку  в  каждом 

нужном  положении,  что  дает  возможность  точно  определить 

расход наружного воздуха, проходящего через воздушную заслонку. 

Позиционер может быть установлен внутри щита управления или на 

его передней панели.

Fig. 17 ZW damper position presetting unit

Рис.17 Позиционер ZW

Supply voltage

Напряжение питания

24V AC

24B AC

Output signal

Управляющий сигнал

0...10V DC

0...10B DC

Protection level

Степень защиты

IP42

WS Service Switch

WS  service  switch  is  used  to  switch  off  the  fan  motor  for  service 

purposes. The WS service switch serves is a safety element that prevents 

the fan motor from unintended switch-on during service work.

Сервисный выключатель WS

Сервисный 

выключатель 

предназначен 

для 

выключения 

двигателя  вентилятора  с  целью  проведения  сервисных  работ. 

Применение  сервисного  выключателя  предотвращает  случайное 

включение  вентилятора  и  тем  самым  обеспечивает  безопасность 

обслуживающего персонала.

Fig. 18 Service Switch

Рис. 18 Сервисный выключатель WS

Type

Тип

WS-3

WS-6

Main circuits: poles

Полюса

3-poles

3-полюсный

6-poles

6-полюсный

Supply circuits switch

Переключатель цепей питания

single or three-phase supply

ток одно- и трёхфазный

three-phase supply

ток трёхфазный

Constant current rate

Номинальный постоянный ток

25A

25A

Protection level

Степень защиты

IP65

IP65

Summary of Contents for ZS-1/1

Page 1: ...71 www juwent com pl HEATING AND VENTILATION UNITS CONTROL AND AUTOMATICS...

Page 2: ...www juwent com pl 72...

Page 3: ...ing elements are adjusted from the outside Internal connections are completely covered and protected to guarantee safe maintenance and normal operation Other benefits of the Power Supply Control Box i...

Page 4: ...id damage to the controller only one device should be connected The controllers do not incorporate short circuit protection RTRD controllers are equipped in thermal protection circuit controlled by th...

Page 5: ...NS TPZ1 TPZ2 RD RT IP65 V MV M ZW TPZ1 TPZ2 Freezing Protection Thermostat TPZ1 TPZ2 Thermostat is recommended for use in the heating and ventilating units with fresh air circulation to protect the he...

Page 6: ...range 8 30O C Output signal 0 10V DC 0 10 DC Protection level IP42 Single RT temperature controller connected to supply and control box can control a group of heating units RT controllers should be m...

Page 7: ...30O C Connector rated load 6 2 A Protection level IP30 Valves V t The isolation valves are widely used in the units to control the flow of heating medium through the heating coils The used three way v...

Page 8: ...signation DN kVS m3 h kVS 3 t O C PN DN20 40 V20 150 20 6 3 20 150 16 V25 150 25 10 20 150 16 V32 150 32 16 20 150 16 V40 150 40 25 20 150 16 S Supply R Return H Heat exchanger Z cut off valve manuall...

Page 9: ...RT controller or TP TPP thermostat Movement of the valve stem is proportional to the control signal from the controller or thermostat MV Valve Actuators can also be adjusted manually and are intended...

Page 10: ...AC Opening closing time 150 s 150 c 150 s 150 c Protection level IP54 IP54 ZW damper position presetting unit ZW damper Position Presetting Unit enables presetting of the damper in any desired positio...

Page 11: ...n thermostat TPZ2 OMY 5x1 mm2 OMY 5x1 2 Speed controller 5 step 1 230V 5 1 230 ARW OMY 3x1 mm2 OMY 3x1 2 Speed controller 5 step 3 400V 5 3 400 RTRD OMY 4x1 mm2 OMY 4x1 2 3 APPLICATIONS 3 1 AIR CIRCUL...

Page 12: ...hile TPZ2 with RT Temperature Controller opening of outside damper M by on off actuator or by the use of ZW damper Position Presetting Unit to move the actuator steplessly ZW damper Position Presettin...

Page 13: ...ecrease in the premises below the set up value leads to the short circuit of heating and start up of the fan at the pre set speed When the temperature in the premises achieves the pre set value the fa...

Page 14: ...The wiring connection and start up diagrams are delivered together with the ordered units due to the various input ranges of the electrical heaters 4 UGW D ZS Y Y Z S 1 3 RD 5 ELECTRICAL CONNECTION D...

Page 15: ...pply voltage 230V AC 230B AC Y1 control signal enable 230V 230B Y2 control signal disable 230V 230B Fig 29 MV actuator constant signal 29 MV Y input control signal 0 10V DC 0 10 DV G0 system zero G ph...

Page 16: ...iagram TERM 0 J Motor connection diagram TERM 1 J TERM 2 J TROPIC 1 TROPIC 2 Motor connection diagram UGW D 10 11 J Motor connection diagram UGW D 10 11 J Motor connection diagram TERM 2 3 4 T Motor c...

Reviews: