Juta CM3024Z Installation And Operation Manual Download Page 3

JUTA Solar Charge Controller

Model :CM3024Z

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Ningbo Star Solar Co.,Ltd Tel:(86) 574 26266608

Fax:(86) 574 26266618 56664636 Email:[email protected]

Http://www.pvsolarchina.com

1

Product introduction 

CM series controller is a kind of intelligent and multifunctional solar charge controller. 
These serial products adopt customized LCD display screen, which makes the operation 
on the interface rather convenient. All the controlling parameters can be reset flexibly to 
satisfy your different needs. CM series controller has the following features:   

Visual LCD graphic symbol     

Intelligent PWM Charging Mode          

Grade auto switch of system voltage     

         

             

       

 

Remote Monitoring Function         

Battery reversed protection            

Brief key operation 

Auto temperature compensation 

Accumulative function of charging & discharging AH 

Adjustable charging & discharging parameter

 

Settable working modes of loads         

Protection for battery back discharging 

Protection for battery low voltage     

Overloading & short-circuit protection 

Delayed auto restart after overloading   

     

 

 

2

Installation Explanation 

Installation

 

Get ready the related tools & cables. We suggest you choose the appropriate cables to 

ensure the current density 

4A/mm

and this is good for reducing cable voltage drop. 

Recommendation

30A using 10mm

cable

50A using 16 mm

cable. 

    Check whether installation place accords with the relative safety rules. Please avoid 

installing and using the controller under the following conditions: wet, dusty places or 
places with flammable and explosive gases.   

  Install the controller at the vertical plane. Please refer to chapter 5 for more detailed 

info about the spacing between the installing holes. In order to make the controller have 
good thermal dissipation, please spare 10cm above & below the controller. 

 As shown as the right figure, connect the loads, battery and solar panels with the 

controller in order. Pay attention to connect the loads, battery and solar panels right. 

  Plug the external thermal sensor into the interface of the thermal-sensor on the left 

of the controller. 

   

 If you need to use the remote monitoring function, please plug one side of the attached 

communication cable into the communication port which is on the right of the controller, 
and connect the other side with computer.

 

Disassemble

: To avoid the accident, please dismantle the solar panels, battery, loads 

from the controller in order. 

Attention: 

Connecting the battery reversed will not damage the controller, but will cause 

safety risk on your loads. 

 
 
 
 
 
 

Summary of Contents for CM3024Z

Page 1: ...ingbo Star Solar Co Ltd Tel 86 574 26266608 Fax 86 574 26266618 56664636 Email Sales pvsolarchina com Http www pvsolarchina com CM30 Solar Charge Controller 30 AMP 12V 24V 48V INTELLIGENT SOLAR CHARGE CONTROLLER INSTALLATION AND OPERATION MANUAL ...

Page 2: ...bo Star Solar Co Ltd Tel 86 574 26266608 Fax 86 574 26266618 56664636 Email Sales pvsolarchina com Http www pvsolarchina com TABLE OF CONTENT 1 Product Introduction 3 2 Installation explanation 4 3 Operation 5 4 Breakdown disposal 10 5 Data Sheet 11 ...

Page 3: ...bles to ensure the current density 4A mm2 and this is good for reducing cable voltage drop Recommendation 30A using 10mm2 cable 50A using 16 mm2 cable Check whether installation place accords with the relative safety rules Please avoid installing and using the controller under the following conditions wet dusty places or places with flammable and explosive gases Install the controller at the verti...

Page 4: ...work setting state Parameter adjusting button Besides at the main interface this button can turn on or turn off the load 3 Parameter review and setting After the controller electrifies right it will enter into the displaying interface of battery voltage This interface is the main interface of the controller Press button to go through the interfaces of the following parameters If the interface can ...

Page 5: ...e accumulating ting AH of sola genera r panels At this interface press button 5 seconds and it can clear 3 7 Review and clearing load accumulative discharging AH umulative tton accumulative generating AH As shown as the right figure the displaying number is the acc discharging AH of loads At this interface press bu 5 seconds and it can clear and setting low voltage protection function rotection es...

Page 6: ...face press button As shown as the right figure it is mode Different numbers represent different load mode 24h indicating normal mode loads are under supplying power without breakdown dark and shun down after working for the delayed setting hours cating light control loads start to supply power after dark and sto after dawn for long 5 seconds the number starts to flicker tton and it means the contr...

Page 7: ...t is more than ic ther exceptional conditions Please contact the distributor or manufacturer DATA SHEET tw e of the rated working current Please restart the controller for times O 5 model parameter CM3024Z CM3048 model p CM3024Z CM3048 arameter rated working 12V 24V 48V installable ma le 7 AWG 16mm2 voltage ximum cab rat g 30A 30A temperature 10 60 ed workin current working volt lar 50V 100V tempe...