3.1 

General recommendations 

 

•  Installation  and  maintenance  must  be  carried  out  with  the  unit 

totally  disengaged  from  its  drive  system  and  must  be  performed  by 
qualified personnel. 

•  Use  adequate  clothing  (avoid  ties,  loose  sleeves,  necklaces  and 

so on) and suitable protection equipments (gloves, protection glasses, 
boots...). 

•  To  prevent  errors  and  hazardous  situations,  establish  what  each 

operator is responsible for in the different maintenance operations. 

• When transporting the pump, use proper slinging. Store the pump 

in stable places. 

•  Make  sure  that  all  the  parts  of  the  unit  are  idle  and  cool,  before 

performing any maintenance operation.  

•  Before  each  maintenance  operation,  stop  the  pump  and  restore 

the atmospheric pressure. 

•  When  the  pump  is  running,  some  parts  may  reach  very  high 

temperatures  (above  100°C).  Use  all  necessary  precautions  to  avoid 
contact.  

•  Operators  working  nearby  must  avoid  prolonged  exposure  to  the 

noise  emitted  by  the  aspirator,  if  not  equipped  with  the  proper  ear-
protection devices. 

• Avoid accidental suction of solids: solids may be projected at high 

speed through the exhaust manifold and cause injures. A filter must be 
mounted on the sunction line. 

•  Do  not  start  the  machine  if  the  protection  devices  provided  for 

transmissions are removed. Replace damaged parts. 

• Pressure relief valve: point the air flux away from the operators. 
• Do not use the aspirator over its designed limits: the machine may 

be damage and the operator may be injured. 

 

 

Do  not  exceed  the  power  supply  parameters 
indicated in the technical tables (see par. 2.4). 

 

3.2 

Intended use 

 

•  The  vacuum  pumps  RV  are  designed  to  convey  filtered  air  into 

systems for the  vacuum production (example:  systems  for the suction 
of  powders  or  liquid  wastes).  Any  other  usage  shall  be  considered 
improper. 

•  Do  not  sack  toxic  substances  and  inflammable  or  explosive 

gasses,  since  the  internal  components  of  the  pump  may  reach  high 
temperatures. 

• Liquids or solids infiltrations can seriously damage the pump. 
•  Do  not run  the  pump  over  its  designed  operating  limits  (see  par. 

2.4): it may break and transmission can be damaged. 

 

 

 

 

Legend of main components 

1. 

Manifold 

5. 

Oil Tank 

9. 

Lubrication pump 

2. 

Vacuum-pressure manifold 

6. 

Tank oil stand 

10. 

Cooling fan 

3. 

Non return valve (rubber ball RV 360) 

7. 

Oil filler cap 

11. 

Air cooling conveyors 

4. 

Non return valve (clapet RV 360) 

8. 

Vane inspection ports 

12. 

Fan protection 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pic. 4.1 

4. Installation 

3. Safety and accident prevention 

11 

10 

10  11 

12 

Summary of Contents for RV360

Page 1: ...IN NS ST TA AL LL LA AT TI IO ON N U US SE E A AN ND D M MA AI IN NT TE EN NA AN NC CE E M MA AN NU UA AL L EN RV360 RV520 Rev 09 21 03 2016 O OR RI IG GI IN NA AL L I IN NS ST TR RU UC CT TI IO ON NS...

Page 2: ...6811 FAX 39 0434 636812 http www jurop it e mail info jurop it 2016 Jurop Azzano Decimo PN Reproduction electronic storage and dissemination even partial are prohibited Jurop reserves the right to mod...

Page 3: ...neral recommendations 9 3 2 Intended use 9 4 Installation pag 9 4 1 Checking upon receipt 10 4 2 Storing in the warehouse 10 4 3 Mounting 11 4 4 Vacuum pressure line 11 4 5 Hydraulic actuator adjustme...

Page 4: ...afety rules are not respected the pump or system can be damaged Suggestions for an environment friendly use of the pump Suggestions for an environment friendly use of the pump The graphic representati...

Page 5: ...ilt in 4 way vacuum pressure manifold Pneumatic actuator available on request Non return valve integrated in the pump manifold RV360 Check valve installed on the pump inlet RV520 Aluminum conveyors Av...

Page 6: ...A B C D E F G H I L M N O P RV 360 25 220 294 830 577 415 443 168 160 175 267 145 192 384 RV 520 29 5 286 334 975 598 429 438 5 156 5 187 5 160 278 5 195 210 392 dimension of RV520 manifold RV360 HDR...

Page 7: ...MANUAL RV360 520 REV 09 21 03 2016 7 32 Jurop SpA Via Crosera n 50 33082 Azzano Decimo PN Italia TEL 39 0434 636811 FAX 39 0434 636812 http www jurop it e mail info jurop it 2 2 Dimensions and arrang...

Page 8: ...ts Vacuum rate Abs pressure 20 40 60 70 80 90 1 5 bar 1 8 bar 2 0 bar m3 h 612 605 595 564 453 310 106 570 550 540 RV 360 l min 10200 10080 9913 9400 7550 5166 1766 9496 9163 8997 kW 14 13 5 13 12 6 1...

Page 9: ...oid accidental suction of solids solids may be projected at high speed through the exhaust manifold and cause injures A filter must be mounted on the sunction line Do not start the machine if the prot...

Page 10: ...the body rotors and sides Then attach again the guards Store in a closed and dry place Renew the preserving oil periodically To temporarily store a used pump follow the instructions below Thoroughly c...

Page 11: ...is also useful to cool down the overheated pumps as well as for their internal wash up Direct the air flow away from the operators Thermostat Pos 8 it must be installed at maximum 150 mm from the exh...

Page 12: ...manufacturer s data See list belove T Max Do not use diven or driving pulleys with a pitch diameter inferior to 160 mm Small pulleys require a high belt tension which may cause premature wear to the...

Page 13: ...cuit and adjust the overpressure safety valve to the lowest possible value Check the oil tank level Increase pressure and rotation speed until operating values are reached 5 1 Starting up of the pump...

Page 14: ...be disconnected drain the liquids accumulated in the separator of the exhaust silencer Once the needed vacuum rate has been reached we recommend reducing the vacuum pump speed to its working speed see...

Page 15: ...Check their right entry in the seat Pic 6 2 Insert a 5 mm stick until it touches the rotor and then mark see Fig 6 3 Turn the rotor slowly until the stick touches the vane in idle position in its sea...

Page 16: ...play between the valve and its seat and of reduced performance or anticlockwise by 1 8 turn 45 to raise it in case of difficult rotation of the valve in its seat Hold the valve in place with the span...

Page 17: ...acuum pump flange 5 by using the threaded holes to extract it Do not lose OR Ring 47 Hold the shaft before extracting the flange the rotor weight must not solicit the internal components Extract the w...

Page 18: ...oupling every 1500 hours We recommend the drive coupling be oiled every 1500 hours Apply coupling hub H1 to vacuum pump axis respecting the position marked during disassembly the grain must go back in...

Page 19: ...way changeover valve in idle position Move the lever to vacuum or pressure mode end stroke Four way changeover valve not correctly registered Adjust the functioning play and lubricate Worn vanes Repla...

Page 20: ...03 2016 20 32 Jurop SpA Via Crosera n 50 33082 Azzano Decimo PN Italia TEL 39 0434 636811 FAX 39 0434 636812 http www jurop it e mail info jurop it RV 360 F IGURE RV 360 ROTATION RIGHT CODE A460809440...

Page 21: ...GALV 1 24 1650022100 REAR RV SHAFT 1 68 4026155909 SCREW TSPEI 10 9 M12X30 GALV 2 25 1650022200 ANTERIOR RV SHAFT 1 69 4026300025 COMPENSATION RING LMKAS100C 2 26 16630040E0 PIPE TANK RV360 RH 1 70 40...

Page 22: ...RV360 ACCESSORIES REV 09 21 03 2016 22 32 Jurop SpA Via Crosera n 50 33082 Azzano Decimo PN Italia TEL 39 0434 636811 FAX 39 0434 636812 http www jurop it e mail info jurop it 3 8 7 6 3 3 11 5 4 1 2 1...

Page 23: ...NIFOLD GASKET 1 H5 16171001E0 SQUARE HDR 1 F4 4026102807 SCREW TE 8 8 M8X25 UNI5931 GALV 12 H6 1622010200 RV CONVEYOR DOWEL PIN 4 F5 4026135504 SCREW 12 9 M10X10 GALV 1 H7 1624042300 HDR RV COUPLING S...

Page 24: ...20 REV 06 21 03 2016 24 32 Jurop SpA Via Crosera n 50 33082 Azzano Decimo PN Italia TEL 39 0434 636811 FAX 39 0434 636812 http www jurop it e mail info jurop it RV 520 F IGURE RV 520 ROTATION RIGHT CO...

Page 25: ...RV SHAFT 1 69 4026300025 COMPENSATION RING LMKAS100C 2 25 1650022200 ANTERIOR RV SHAFT 1 70 4026305508 SELF LOCKING NUT M12 2 26 16630050E0 PIPE TANK RV520 RH 1 71 4026308005 NUT M8 GALV 2 16630051E0...

Page 26: ...DATA SHEET RV520 ACCESSORIES 26 32 Jurop SpA Via Crosera n 50 33082 Azzano Decimo PN Italia TEL 39 0434 636811 FAX 39 0434 636812 http www jurop it e mail info jurop it RV 520 ACCESSORIES 9 7 3 4 3 4...

Page 27: ...C5 1610101100 CONVEYOR FLANGE 1 C6 1627102400 CONVEYOR 100 1 11 143029KRB0 KIT HYDRAULIC ACTUATOR C7 4022200310 OR 6362 VIT 1 I1 143027T6B0 CILINDER 1 C8 4026102808 SCREW TE M8X30 UNI5739 GALV 4 I2 1...

Page 28: ...ING NUT M12 4 H6 1622010200 RV CONVEYOR DOWEL PIN 4 H23 4026350505 WASHER GROWER 8 GALV 6 H7 1624042300 HDR RV COUPLING SEAL SPACER 2 H24 4026350506 WASHER GROWER 10 GALV 6 H8 1627105200 RV CONVEYOR W...

Page 29: ...he disassemble Do not use the threaded holes that can be seen on the locking collar front These are used for the disassemble Pic 9 1 E Threaded holes for disassembly Install the steel hub and the fan...

Page 30: ...pattern 3 time If necessary check one last time the screws Torque 16Nm to be sure that they have been tightened evenly Pic 9 7 Disassemble Remove the 4 screws that keep the locking collar in place Pi...

Page 31: ...REV 09 21 03 2016 31 32 Jurop SpA Via Crosera n 50 33082 Azzano Decimo PN Italia TEL 39 0434 636811 FAX 39 0434 636812 http www jurop it e mail info jurop it...

Page 32: ...jurop it Model Issue date Revision No Revision date Filled out by Viewed by RV 360 520 10 09 2013 09 21 03 2016 U T A T Jurop SpA Via Crosera 50 33082 Azzano Decimo PN ITALY Tel 39 0434 636811 Fax 39...

Reviews: