I
NSTALLATION
,
USE AND MAINTENANCE MANUAL
–
RV360
-
520
R
EV
.
09
21-03-2016
8 / 32
Jurop
SpA
Via Crosera n° 50
33082 Azzano Decimo, PN (Italia)
T
EL
.
+39
0434
636811
F
AX
.
+39
0434
636812
http://www.jurop.it
e-mail: [email protected]
2.3
Performances
Performances referred to vacuum pump operating at max. speed. Actual performance may vary of +/- 5%.
Performances
RV
360
RV
520
Air flow under free air condition
10200 l/min
– 612 m³/h
14700 l/min
- 882 m³/h
Air flow 60% vacuum rate
9400 l/min
- 564 m³/h
12915 l/min
- 775 m³/h
Max. vacuum at continuous duty
80%
80%
Max. vacuum
95%
95%
Power required at free port
14 kW
19 kW
Power required at max. vacuum
11 kW
16 kW
Airflow at 0.5 relative bar (1.5 abs.)
18 kW
24 kW
Airflow at 1.0 relative bar (2.0 abs.)
22 kW
30 kW
Max. relative pressure
1,0 bar (2,0 bar abs)
1,0 bar (2,0 bar abs)
Oil consumption
140 g/h
160 g/h
Oil tank capacity
4 l
4 l
REFERENCE CONDITIONS
Conveyed gas: air
Vacuum condition: atmospheric discharge.
Absolute reference pressure: 1013mbar
Ambient reference temperature: 20°C
Vacuum functioning: free outlet
Pressure condition: atmospheric suction.
Flow / Power
Model
Free ports
Vacuum rate
Abs. pressure
20%
40%
60%
70%
80%
90%
1,5 bar
1,8 bar
2,0 bar
m
3
/h
612
605
595
564
453
310
106
570
550
540
RV 360
l/min
10200
10080
9913
9400
7550
5166
1766
9496
9163
8997
kW
14
13,5
13
12,6
12,3
11,9
11,2
18
20,5
22
m
3
/h
882
860
840
775
670
480
150
780
740
712
RV 520
l/min
14700
14330
14000
12915
11165
8000
2500
13165
12330
11865
kW
19
18,2
17,7
16,9
16,4
16,2
16,1
24
27,5
30
Note
: data at nominal speed.
Sound pressure level
RV 360
RV 520
Max. speed, 60% vacuum rate*
72 dB(A)
73 dB(A)
* : Noise of pump with exhaust silencer cod. 15470 D2C B0. Distance: 7m in open field.
2.4
Usage limitations
Model
Max. Speed – Operating speed (RPM)
P
2
(bar ABS)
T
2
(°C)
T
2
- T
1
(°C)
Environmental
Temperature
Minimum
Ordinary
Max
RV 360
800 rpm
1100 rpm
1300 rpm
2,0 bar
180°C
150°C
-20 / +40°C
RV 520
800 rpm
1100 rpm
1300 rpm
2,0 bar
180°C
150°C
-20 / +40°C
P
1
: absolute pressure during suction
T
1
: temperature during suction
P
2
: absolute pressure during delivery
T
2
: temperature during delivery
2.5
Lubrication
Room.
Temp.
Viscosity
Type
ENI
ESSO
SHELL
TOTAL
MOBIL
BP
TEXACO
HAVOLINE
Under 10°C
ISO VG 46
Mineral oil
Acer 46
Nuto 46
Morlina oil 46
Drosera MS 46
Nuto H 46
Bartran HV 46
Rando HD 46
Over 10°C
ISO VG 150
Mineral oil
Acer 150
Nuto 150
Morlina oil 150
Drosera MS 150
Nuto H 150
Bartran HV 150
Rando HD 150