Use electrical cable of the type NYM with the
following conductor cross section:
Make certain that the cable is voltage-free
and then connect the thermostat with the
three-conductor cable to the gas heater ac-
cording to the connection plan (
to
).
4.4
Putting into Operation
After the electrical cable is connected, insert
the top part of the thermostat
(a)
onto the
base
(b)
, and put the gas heater into operati-
on.
5 Operation
To set the switching times, remove the cover
(e)
of the timer (
).
The TRQ 21 W room thermostat has the fo-
lowing control elements (
and
):
e
Cover
f
Mode switch
g
Temperature setting knob - normal
mode
h
Temperature setting knob - reduced
mode
i
Plexiglas disk with printed clock hand
j
7-Day ring
k
Storage for reserve riders
l
Riders in red or blue
m
Time marker for 7-day ring
n
Brief operating instructions:
In the compartment on the right side of
the base, a small instruction manual
(JU 1007) can be found. It contains all
essentials for operation in brief form.
5.1
Mode Switch (f)
The following operating modes are possible:
Automatic switching between normal
and reduced modes at the times set on
the timer.
Normal mode: Continuous regulation
of the room temperature to the value
set with the knob
(g)
.
Reduced mode: Continuous regulation
of the room temperature to the value
set with the knob
(h)
.
5.2
Temperature Setting Knobs (g) and (h)
With these setting knobs, the desired room
temperatures for normal mode
(g)
or redu-
ced modes
(h)
are set. The temperature ran-
ge of each is from 6 to 30 °C.
5.3 Timer
With the selection of the appropriate opera-
ting mode, the timer makes possible the au-
tomatic switching between normal and redu-
ced modes. The shortest switching interval
(closest distance between two riders on the
7-day ring ) is two hours. The positioning ac-
curacy (distance between two adjacent posi-
tions on the 7-day ring) is 30 min.
5.3.1
Setting the Time
Turn the Plexiglas disk with the printed minu-
te hand
(i)
to set the actual time of day. Turn
the disk only in the clockwise direction. The
7-day ring
(j)
must not be turned. Observe
that the clock runs in 7-day operation. The
time setting (24 hr and weekday) can be
read off of the 7-day ring
(j)
at the time mar-
ker
(m)
.
5.3.2
Setting the Switching Times
• Red rider
= Normal mode.
• Blue rider
= Reduced mode.
For correct operation of the timer, the riders
must be positioned alternately in red/blue se-
quence.
Stick the red and blue riders
(l)
for each day
at the desired position of the 7-day ring
(j)
.
Riders that are not used remain in the stora-
ge position
(k)
.
3
1
1
11
6
GB
8
TRQ 21 W
Cable length:
Cross section:
to 20 m
2
0.75 to 1.5 mm
2
to 30 m
2
1.00 to 1.5 mm
2
more than 30 m
2
1.50 mm
2
English