Eliminating minor faults yourself
Before you call customer service:
Please check whether you can eliminate the fault yourself based on the following
information.
Customer service will charge you for advice – even if the appliance is still under
guarantee!
Fault
Possible cause
Remedial action
Bottom of the
refrigerator
compartment is wet.
The condensation
channel or drainage
hole are blocked.
Clean the condensation channel
and the drainage hole. See chapter
Cleaning the appliance. Fig.
6
There is a thick layer
of frost in the freezer
compartment.
Defrosting the freezer compartment
(see chapter Defrosting). Always
ensure that the freezer compartment
door is closed properly.
The frozen food is
frozen solid.
Loosen frozen food with a blunt
object. Do not use a knife or pointed
object.
Appliance has no
refrigeration capacity.
The light does not
work.
The display does not
illuminate.
Appliance has been
switched off.
Press the On/Off button.
Power failure.
Check whether the power is on.
The fuse has been
switched off.
Check the fuse.
The mains plug has
not been inserted
properly.
Check whether the mains plug is
secure.
Temperature differs
greatly from the set
value.
In some cases it is adequate
to switch off the appliance
for 5 minutes.
If the temperature is too high wait
a few hours and check whether the
temperature has approached the set
value.
If the temperature is too low check
the temperature again the next day.