background image

Laser and LED Safety Guidelines and Warnings

Juniper Networks devices are equipped with laser transmitters, which are considered a
Class 1 Laser Product by the U.S. Food and Drug Administration and are evaluated as a
Class 1 Laser Product per EN 60825-1 requirements.

Observe the following guidelines and warnings:

General Laser Safety Guidelines on page 88

Class 1 Laser Product Warning on page 88

Class 1 LED Product Warning on page 89

Laser Beam Warning on page 89

General Laser Safety Guidelines

When working around ports that support optical transceivers, observe the following
safety guidelines to prevent eye injury:

Do not look into unterminated ports or at fibers that connect to unknown sources.

Do not examine unterminated optical ports with optical instruments.

Avoid direct exposure to the beam.

WARNING:

Unterminated optical connectors can emit invisible laser

radiation. The lens in the human eye focuses all the laser power on the
retina, so focusing the eye directly on a laser source—even a low-power
laser—could permanently damage the eye.

Class 1 Laser Product Warning

WARNING:

Class 1 laser product.

Waarschuwing

Klasse-1 laser produkt.

Varoitus

Luokan 1 lasertuote.

Attention

Produit laser de classe I.

Warnung

Laserprodukt der Klasse 1.

Avvertenza

Prodotto laser di Classe 1.

Advarsel

Laserprodukt av klasse 1.

Aviso

Produto laser de classe 1.

¡Atención!

Producto láser Clase I.

Copyright © 2018, Juniper Networks, Inc.

88

JRR200 Route Reflector Hardware Guide

Summary of Contents for JRR200

Page 1: ...JRR200 Route Reflector Hardware Guide Modified 2018 08 15 Copyright 2018 Juniper Networks Inc...

Page 2: ...orks Inc All rights reserved The information in this document is current as of the date on the title page YEAR 2000 NOTICE Juniper Networks hardware and software products are Year 2000 compliant Junos...

Page 3: ...em 21 JRR200 Route Reflector Air Flow and Cooling System 22 JRR200 Power System 22 JRR200 Route Reflector AC Power Supply 23 JRR200 Route Reflector AC Power Supply Specifications 24 JRR200 Route Refle...

Page 4: ...ices 48 Performing the Initial Configuration for JRR200 48 JRR200 Route Reflector Initial Configuration Using the CLI 49 JRR200 Route Reflector Factory Default Settings 50 Viewing Factory Default Sett...

Page 5: ...Information 75 General Safety Guidelines and Warnings 76 Definitions of Safety Warning Levels 77 Restricted Access Warning 78 Fire Safety Requirements 80 Fire Suppression 80 Fire Suppression Equipmen...

Page 6: ...wer Supplies Disconnection Warning 104 TN Power Warning 105 Action to Take After an Electrical Accident 106 JRR200 Agency Approvals and Regulatory Compliance Information 106 Agency Approvals 106 Acous...

Page 7: ...ow Through the Chassis 33 Chapter 3 Initial Installation and Configuration 39 Figure 12 Attaching the Mounting Ears and Fixed Brackets 42 Figure 13 Securing the Mounting Ears to the Rack 43 Figure 14...

Page 8: ...Copyright 2018 Juniper Networks Inc viii JRR200 Route Reflector Hardware Guide...

Page 9: ...t LEDs 27 Table 13 DC Power Supply Specifications 27 Chapter 2 Site Planning Preparation and Specifications 29 Table 14 Site Preparation Checklist for JRR200 Route Reflector 29 Table 15 Environmental...

Page 10: ...Copyright 2018 Juniper Networks Inc x JRR200 Route Reflector Hardware Guide...

Page 11: ...www juniper net documentation If the information in the latest release notes differs from the information in the documentation follow the product Release Notes Juniper Networks Books publishes books...

Page 12: ...mode type the configure command user host configure Represents text that you type Bold text like this user host show chassis alarms No alarms currently active Represents output that appears on the ter...

Page 13: ...ets edit routing options static route default nexthop address retain Identifies a level in the configuration hierarchy Indention and braces Identifies a leaf statement at a configuration hierarchy lev...

Page 14: ...self service portal called the Customer Support Center CSC that provides you with the following features Find CSC offerings https www juniper net customers support Search for known bugs https prsearch...

Page 15: ...For international or direct dial options in countries without toll free numbers see https www juniper net support requesting support html xv Copyright 2018 Juniper Networks Inc About the Documentation...

Page 16: ...Copyright 2018 Juniper Networks Inc xvi JRR200 Route Reflector Hardware Guide...

Page 17: ...RIB entries The JRR200 route reflector comes with eight 1 10 Gigabit Ethernet SFP ports 64 GB of DDR4 memory and two 240 GB solid state drives SSDs in a RAID1 configuration The JRR200 route reflector...

Page 18: ...Description Component Number Gigabit Ethernet port to connect to the device over the network Management port 1 Two USB 2 0 ports that accept a USB storage device USB ports 2 The two HA ports are not...

Page 19: ...e Blinking red noncritical alarm Off the system is not receiving power Status Blinking green indicates hard disk drive SSD activity SSD Management Port LEDs The management port has two LEDs that indic...

Page 20: ...There is no link established Speed Activity LED on the right 2 JRR200 Route Reflector Chassis Rear Panel Figure 4 on page 20 shows the rear panel of the JRR200 Route Reflector Table 7 on page 20 list...

Page 21: ...es redundancy Fan trays 5 Two power supply slots Each power supply contains a power cord outlet Two 650 W DC or AC power supplies are provided with the JRR200 route reflector Power supply 6 JRR200 Rou...

Page 22: ...ion by reducing the performance or shutting down some of the chassis components However if the ambient maximum temperature exceeds the warning level and the system cannot be adequately cooled then the...

Page 23: ...n internal cooling system Each AC power supply unit weighs approximately 2 3 lb and consists of one AC appliance inlet a fan and LEDs for monitoring the status of the power supply unit It gives an out...

Page 24: ...are unlit either the AC power cord is not installed properly or the power supply unit fuse has failed If the AC LED is lit and the DC LED is unlit the AC power supply unit is installed properly but th...

Page 25: ...NEC Section 400 8 NFPA 75 5 2 2 and 210 52 and Canadian Electrical Code CEC Section 4 010 3 Table 11 on page 25 provides power cord specifications and Figure 8 on page 25 depicts the plug on the AC p...

Page 26: ...power supply unit fails or is removed the other power supply unit redistributes the electrical load without interruption Each power supply unit is cooled by its own internal cooling system Each DC pow...

Page 27: ...upply unit failure On steadily Amber Fault Invalid power supply unit Blinking Power supply unit is functioning normally Off Unlit JRR200 Route Reflector DC Power Supply Specifications Table 13 on page...

Page 28: ...Copyright 2018 Juniper Networks Inc 28 JRR200 Route Reflector Hardware Guide...

Page 29: ...hecklist of tasks you need to perform when preparing a site for installing the JRR200 Route Reflector Table 14 Site Preparation Checklist for JRR200 Route Reflector Notes Date Performed By Additional...

Page 30: ...e components being connected Plan the cable routing and management JRR200 Site Guidelines and Requirements JRR200 Route Reflector Environmental Specifications on page 30 General Site Guidelines on pag...

Page 31: ...such as metal flakes Follow prescribed airflow guidelines to ensure that the cooling system functions properly and that exhaust from other equipment does not blow into the intake vents of the device...

Page 32: ...frequency interference If your site is susceptible to problems with electromagnetic compatibility EMC particularly from lightning or radio transmitters seek expert advice Some of the problems caused b...

Page 33: ...RR200 route reflector Table 17 Clearance Requirements for the JRR200 Route Reflector Requirement for Clearance Recommended Clearance Location Space for service personnel to remove and install hardware...

Page 34: ...ce can be mounted in any rack that provides holes spaced at that distance Mounting bracket hole spacing Ensure that the rack complies with the size and strength standards of a 19 in rack as defined in...

Page 35: ...ctor Route and dress all cables to minimize the blockage of airflow to and from the chassis A cabinet larger than the minimum required provides better airflow and reduces the chance of overheating Cab...

Page 36: ...for the JRR200 Route Reflector on page 37 Management Port Connector Pinout Information for the JRR200 Route Reflector The port on the front panel labeled MGMT is an autosensing 10 100 1000 Mbps Ether...

Page 37: ...J 45 console connector An Ethernet cable that has an RJ 45 connector at either end and an RJ 45 to DB 9 serial port adapter are supplied with the route reflector Table 21 Console Port Connector Pinout...

Page 38: ...Copyright 2018 Juniper Networks Inc 38 JRR200 Route Reflector Hardware Guide...

Page 39: ...power supplies if they are not pre installed See Installing a JRR200 Route Reflector AC Power Supply on page 57 Installing a JRR200 Route Reflector DC Power Supply on page 59 3 Mount the JRR200 Route...

Page 40: ...list specifies the part numbers and carries a brief description of each part in your order 5 Save the shipping carton and packing materials in case you need to move or ship the JRR200 route reflector...

Page 41: ...RR200 route reflector on four posts in a rack 1 Verify that the site meets the requirements described in Site Preparation Checklist for the JRR200 Route Reflector on page 29 2 Place the rack or cabine...

Page 42: ...ng the route reflector into the rack To mount the JRR200 route reflector on a four post rack 1 Attach the front mounting brackets and the side mounting rails to the chassis by using the flat head scre...

Page 43: ...ecting the JRR200 to Power Connect the Grounding Cable on page 43 Connecting Power to an AC Powered JRR200 Route Reflector on page 44 Connecting Power to a DC Powered JRR200 Route Reflector on page 46...

Page 44: ...you have a power cord appropriate for your geographical location available to connect AC power to the JRR200 Route Reflector Before you begin connecting AC power Ensure that you have taken the necessa...

Page 45: ...he power supply in the device to a grounded AC power outlet by using the power cord 5 Insert the power cord plug into an AC power source outlet 6 Repeat steps 4 and 5 for the second AC power supply 7...

Page 46: ...Before performing the following procedure ensure that there is no power in the DC circuit To ensure that all power is cut off locate the circuit breaker on the panel board that services the DC circui...

Page 47: ...s on the faceplate Save this cover for future use 5 Remove the screws on the terminals by using a number 2 Phillips screwdriver 6 Secure each positive DC source power cable lug to a RTN return termina...

Page 48: ...0 route reflector and the other end into the DB 9 serial port adapter g100086 Con sole port RJ 45 cab le Serial port 3 Connect the DB 9 serial port adapter end of the RJ 45 cable to the serial port of...

Page 49: ...the management interface optional required only if you do not connect the MGMT port directly to the management device root set routing options static route destination prefix next hop gateway 6 Commit...

Page 50: ...root exit JRR200 Route Reflector Factory Default Settings Your JRR200 route reflector comes configured with a factory default configuration which has the ZTP configurations enabled when the JRR200 rou...

Page 51: ...nit 0 family inet dhcp interfaces em8 unit 0 family inet dhcp interfaces em9 unit 0 family inet dhcp chassis auto image upgrade system processes dhcp service traceoptions file dhcp_logfile size 10m le...

Page 52: ...file list etc config 3 View the required default config file user host file show etc config config file name When you commit changes to the configuration a new configuration file is created which bec...

Page 53: ...sure that all power and grounding cables are arranged so that they do not obstruct access to other device components Check the status LEDs on the front panel of the JRR200 route reflector Periodicall...

Page 54: ...nning at normal speed Replacing the JRR200 Route Reflector Fan Tray Each fan tray is a field replaceable unit FRU installed in the rear panel of JRR200 route reflector You can remove and replace the f...

Page 55: ...r W Load 12 10 120 18 PEM 1 status State Online Airflow Front to Back Temperature OK DC Output Voltage V Current A Power W Load 12 10 120 18 Make sure that the power and grounding cables are arranged...

Page 56: ...y To remove a power supply from JRR200 route reflector see Figure 16 on page 57 1 Place the antistatic bag or the antistatic mat on a flat stable surface 2 Attach an electrostatic discharge ESD ground...

Page 57: ...s 2 If the power supply slot has a cover panel on it with one hand slide the ejector lever toward the left until it stops and using the other hand pull the handle of the cover panel outward to remove...

Page 58: ...Route Reflector DC Power Supply Ensure that you have the following parts and tools available ESD grounding strap Phillips screwdriver number 2 Antistatic bag or an antistatic mat Replacement power su...

Page 59: ...y out of the chassis Figure 18 Removing a DC Power Supply g0052 0 9 10 Place the power supply in the antistatic bag or on the antistatic mat placed on a flat stable surface Installing a JRR200 Route R...

Page 60: ...oint Putting fasteners on the loops helps maintain their shape Keep the cable connections clean and free of dust and other particles which can cause drops in the received power level Always inspect ca...

Page 61: ...approved alcohol free fiber optic cable cleaning kit such as the Opptex Cletop S Fiber Cleaner Follow the directions for the cleaning kit you use Replacing an SFP Transceiver on JRR200 Route Reflecto...

Page 62: ...7 Using your fingers grasp the body of the transceiver and pull it the rest of the way out of the interface port 8 Place a rubber safety cap over the transceiver 9 Place the removed transceiver on an...

Page 63: ...the ejector handle of the transceiver 7 Remove the rubber safety cap from the transceiver and the end of the cable Insert the cable into the transceiver WARNING Do not look directly into a fiber optic...

Page 64: ...Copyright 2018 Juniper Networks Inc 64 JRR200 Route Reflector Hardware Guide...

Page 65: ...about network connectivity derived from the ping and traceroute utilities JTAC If you need assistance during troubleshooting you can contact the Juniper Networks Technical Assistance Center JTAC by u...

Page 66: ...Check the room temperature Check the air flow Run all the Fans at full speed Open a support case using the Case Manager link at https www juniper net support or call 1 888 314 5822 toll free within t...

Page 67: ...om outside the United States Input failure to the power supply Yellow minor Open a support case using the Case Manager link at https www juniper net support or call 1 888 314 5822 toll free within the...

Page 68: ...ed are of the same type Mix of AC and DC power supplies installed Yellow minor Check if there is any power supply issue to the USB slot Check for the port level failures Check for USB link to port fro...

Page 69: ...onent to Juniper Networks for repair or replacement follow this procedure 1 Determine the part number and serial number of the JRR200 route reflector or component See Locating the Serial Number on the...

Page 70: ...irflow AFO In the above output SFP or the PIC information is not displayed To view the SFP or the PIC information you need to enter into the host OS and use ethtool m interface name to get the details...

Page 71: ...If contacting JTAC by telephone enter your 11 digit case number followed by the pound key if this is an existing case or press the star key to be routed to the next available support engineer When re...

Page 72: ...console or other management device connected to the JRR200 route reflector enter CLI operational mode and issue the following command to shut down the JRR200 route reflector software user host reques...

Page 73: ...is adequately protected with packing materials and packed so that the pieces are prevented from moving around inside the carton Use the original shipping materials if they are available Place the ind...

Page 74: ...Copyright 2018 Juniper Networks Inc 74 JRR200 Route Reflector Hardware Guide...

Page 75: ...iation from Open Port Apertures Warning on page 90 Maintenance and Operational Safety Guidelines and Warnings on page 91 General Electrical Safety Guidelines and Warnings on page 96 Prevention of Elec...

Page 76: ...al storms Never install electrical jacks in wet locations unless the jacks are specifically designed for wet environments Operate the device only when it is properly grounded Ensure that the separate...

Page 77: ...ith standard practices for preventing accidents Waarschuwing Dit waarschuwingssymbool betekent gevaar U verkeert in een situatie die lichamelijk letsel kan veroorzaken Voordat u aan enige apparatuur g...

Page 78: ...ue possam prevenir poss veis acidentes Atenci n Este s mbolo de aviso significa peligro Existe riesgo para su integridad f sica Antes de manipular cualquier equipo considerar los riesgos que entra a l...

Page 79: ...in un area ad accesso limitato Un area ad accesso limitato un area accessibile solo a personale di assistenza tramite un attrezzo speciale lucchetto o altri dispositivi di sicurezza ed controllata dal...

Page 80: ...xide and Halotron are most effective for suppressing electrical fires Type C fire extinguishers displace oxygen from the point of combustion to eliminate the fire For extinguishing fire on or around e...

Page 81: ...ng b r montere eller bytte ut dette utstyret Aviso Este equipamento dever ser instalado ou substitu do apenas por pessoal devidamente treinado e qualificado Atenci n Estos equipos deben ser instalados...

Page 82: ...o sistema sua fonte de energia Atenci n Ver las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Varning L s installationsanvisningarna innan du kopplar systemet till...

Page 83: ...usare una rampa con pendenza superiore a 10 gradi Advarsel Bruk aldri en rampe som heller mer enn 10 grader Aviso N o utilize uma rampa com uma inclina o superior a 10 graus Atenci n No usar una rampa...

Page 84: ...toestel in het rek monteert of het daar een servicebeurt geeft Varoitus Kun laite asetetaan telineeseen tai huolletaan sen ollessa telineess onnoudatettavaerityisi varotoimiaj rjestelm nvakavuudens i...

Page 85: ...evitare infortuni fisici durante il montaggio o la manutenzione di questa unit in un supporto occorre osservare speciali precauzioni per garantire che il sistema rimanga stabile Le seguenti direttive...

Page 86: ...tabiliza o instale o antes de montar ou reparar a unidade Atenci n Para evitar lesiones durante el montaje de este equipo sobre un bastidor oeriormente durante su mantenimiento se debe poner mucho cui...

Page 87: ...is nt laite on yhdistetty maahan normaalik yt n aikana Attention Cet quipement doit tre reli la terre S assurer que l appareil h te est reli la terre lors de l utilisation normale Warnung Dieses Ger...

Page 88: ...ok into unterminated ports or at fibers that connect to unknown sources Do not examine unterminated optical ports with optical instruments Avoid direct exposure to the beam WARNING Unterminated optica...

Page 89: ...truments Waarschuwing Niet in de straal staren of hem rechtstreeks bekijken met optische instrumenten Varoitus l katso s teeseen l k tarkastele sit suoraan optisen laitteen avulla Attention Ne pas fix...

Page 90: ...emittieren wenn kein Glasfaserkabel angeschlossen ist Vermeiden Sie es sich den Strahlungen auszusetzen und starren Sie nicht in die ffnungen Avvertenza Quando i cavi in fibra non sono inseriti radia...

Page 91: ...tajan suosittelema H vit k ytetyt akut valmistajan ohjeiden mukaan Attention Danger d explosion si la pile n est pas remplac e correctement Ne la remplacer que par une pile de type semblable ou quival...

Page 92: ...mmen lassen Varoitus Ennen kuin ty skentelet voimavirtajohtoihin kytkettyjen laitteiden parissa ota pois kaikki korut sormukset kaulakorut ja kellot mukaan lukien Metalliesineet kuumenevat kun ne ovat...

Page 93: ...arbetar p utrustning som r kopplad till kraftledningar Metallobjekt hettas upp n r de kopplas ihop med str m och jord och kan f rorsaka allvarliga br nnskador metallobjekt kan ocks sammansvetsas med...

Page 94: ...routeurs de la gamme Juniper Networks switch ne l utilisez pas dans une zone o la temp rature ambiante est sup rieure 40 C Pour permettre un flot d air constant d gagez un espace d au moins 15 2 cm au...

Page 95: ...lations Waarschuwing Dit produkt dient volgens alle landelijke wetten en voorschriften te worden afgedankt Varoitus T m n tuotteen lopullisesta h vitt misest tulee huolehtia kaikkia valtakunnallisia l...

Page 96: ...ational and international electrical codes United States National Fire Protection Association NFPA 70 United States National Electrical Code Other countries International Electromechanical Commission...

Page 97: ...onent in its antistatic bag see Figure 21 on page 98 in one hand and touch the exposed bare metal of the device with the other hand immediately before inserting the component into the device WARNING F...

Page 98: ...SHOCK ATTENTION CET APPAREIL COMPORTE PLUS D UN CORDON D ALIMENTATION AFIN DE PR VENIR LES CHOCS LECTRIQUES D BRANCHER TOUT CORDON D ALIMENTATION AVANT DE FAIRE LE D PANNAGE AC powered devices are shi...

Page 99: ...proximit d une alimentation lectrique d brancher le cordon d alimentation des unit s en courant alternatif Warnung Bevor Sie an einem Chassis oder in der N he von Netzger ten arbeiten ziehen Sie bei W...

Page 100: ...tiquer l une quelconque des proc dures ci dessous v rifier que le circuit en courant continu n est plus sous tension Pour en tre s r localiser le disjoncteur situ sur le panneau de service du circuit...

Page 101: ...pplare i FR N l get DC Power Grounding Requirements and Warning An insulated grounding conductor that is identical in size to the grounded and ungrounded branch circuit supply conductors but is identi...

Page 102: ...n utilisant les crochets appropri s l extr mit de c blage En reliant la puissance l ordre appropri de c blage est rectifi pour rectifier RTN RTN puis 48 V 48 V En d branchant la puissance l ordre appr...

Page 103: ...ngssekvens ar jord till jord RTN till RTN 48 V till 48 V Korrekt kopplas kopplingssekvens ar 48 V till 48 V RTN till RTN jord till jord DC Power Wiring Terminations Warning WARNING When stranded wirin...

Page 104: ...rmina es de cabo em circuito fechado e planas com terminais de orelha voltados para cima Estas termina es de cabo dever o ser do tamanho apropriado para os respectivos cabos e dever o prender simultan...

Page 105: ...remover a fonte de alimenta o de energia dever o ser desconectadas todas as conex es existentes Atenci n Esta unidad tiene m s de una conexi n de suministros de alimentaci n para eliminar la alimentac...

Page 106: ...im then call for help JRR200 Agency Approvals and Regulatory Compliance Information Agency Approvals on page 106 Acoustic Noise Compliance Statements on page 107 EMC Requirements on page 108 Agency Ap...

Page 107: ...4 3 Radiated Immunity EN 61000 4 4 EFT EN 61000 4 5 Surge EN 61000 4 6 Conducted Immunity EN 61000 4 11 Voltage Dips and Sags EN 55024 A1 A2 1998 Information Technology 1KV 2KV surge required no 4KV D...

Page 108: ...his product may cause radio interference in which case the user may be required to take adequate measures VCCI A United States The JRR200 Route Reflector has been tested and found to comply with the l...

Reviews: