.06.

    there are any damages or severe scratch.

· 

 

Make sure the fixture is operated by qualified personnel who knows the fixture 

before using.

· 

 

Keep the original packages if any second shipment is needed.

· 

 

Don’t tr y to change the fixtures without any instruction by the manufacturer or 

the appointed repairing agencies. 

· 

 

It is not in warranty range if there are any malfunctions from not following the 

user manual to operate or any illegal operation, like shock short circuit, electronic 

shock , lamp broke, etc.

Cautions: 

For added protection mount the fixtures in areas outside walking paths, 

seating areas, or in areas were the fixture might be reached by unauthorized 

personnel.

Before mounting the fixture to any surface, make sure that the installation area can 

hold a minimum point load of 10 times the device’s weight.

Fixture installation must always be secured with a secondar y safety attachment, such 

as an appropriate safety cable.

Never stand directly below the device when mounting, removing, or ser vicing the 

fixture.

from a ceiling, or set on a flat level surface (see illustration below). Be sure this fixture 

is kept at least 0.5m (1.5 ft) away from any flammable materials (decoration etc.).

Always use and install the supplied safety cable as a safety measure to prevent 

accidental damage and/or injur y in the event the clamp fails.

Mounting points: 

Overhead mounting requires extensive experience, including 

amongst others calculating working load limits, a fine knowledge of the installation 

material being used, and periodic safety inspection of all installation material and 

the fixture. If you lack these qualifications, do not attempt the installation yourself. 

Improper installation can result in bodily injur y.

Be sure to complete all rigging and installation procedures before connecting the 

main power cord to the appropriate wall outlet.

INSTALLATIONS

6

MENU OPERATIONS

8

.09.

LCD DISPLAY

FUNC

UP 

DOWN

ENTER

XXX°C/°F

A001~AXXX

 CH14 mode

 CH16 

Internal Program1~8  Master/Alone

Internal Program1~8  Master/Alone

Yes/No

Wire DMX

Wireless DMX

Act WDMX & Out

Reverse PAN(On/Off)

Reverse TILT (On/Off)

Select PAN  540°/360°/630° 

Select TILT 270°/90°/180°

Mic sensitivity  0~99%

XXXX(Hours)

V1.0~V9.9

On/Off

Total reset

PAN/TILT reset

Color reset

Gobo reset

Strobe reset

The Others reset

PAN=XXX……

PAN=XXX……

Yes/No

mode

DMX address

Channel mode

Auto run

Music control

Reset default

Signal set

PAN / TILT

UI SET

Lamp Hours

Temperature

Software version

Lamp

Reset

Channel

Calibration

Clear lamp time

Scan fast mode

(On/Off)

Function 

mode

Option

Information

Manual 

control

Advanced

(Access Code 088)

M

E

N

U

DMX address setting

Standard mode

Vector mode

Auto run

Sound control

Reset default

Wire DMX

Wireless DMX

Act WDMX & Out

Reverse PAN

Reverse TILT

PAN degree,default is 540°

TILT degree,default is 270°

Mic sensitivity

Lamp hours

Current temperature

Software version

Lamp ON/OFF

Total reset

PAN/TILT reset

Color reset

Gobo reset

Strobe reset

The others reset

Channel control

Calibration

Clear lamp time

Speed Mode

Summary of Contents for JNR mini-beam 230

Page 1: ...JNR MINI BEAM 230 JNR 8129 PR LIGHTING LTD http www pr lighting com 1582 Xingye Avenue Nancun Panyu Guangzhou 511442 China TEL 86 20 3995 2888 ...

Page 2: ...ay arise This is a normal process and does not necessarily mean that the device is defective it should decrease gradually Please don t project the beam onto combustible substances Fixtures cannot be installed on combustible substances keep more than 50cm distance with wall for smooth air flow so there should be no shelter for fans and ventilation for heat radiation If the external flexible cable o...

Page 3: ...during the inspection 1 All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations on the housing color lenses fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply cables m...

Page 4: ...IN OUT Fan cooling system Constant temperature readout and management function Lamp using time readable on the display 35 45 C max ambient temperature IP20 protection rating 55dB at 3 dB rating 2 1 4 turn fastening Omega clamps 1 Safety attachment point available OSRAM 16 facet prism with 11 colors plus open 6 facet 8 facet prism with variable speed and direction Combined prism effect by 16 facet ...

Page 5: ... Gobo 4 shake slow to fast Gobo 5 shake slow to fast Gobo 6 shake slow to fast Gobo 7 shake slow to fast Gobo 8 shake slow to fast Gobo 9 shake slow to fast Gobo 10 shake slow to fast Gobo 11 shake slow to fast Gobo 12 shake slow to fast Gobo 13 shake slow to fast Gobo 14 shake slow to fast Gobo 15 shake slow to fast Gobo 16 shake slow to fast Rot gobo wheel cont rotation slow to fast Shutter clos...

Page 6: ...ion It s recommended to replace the units if MINI BEAM 230 2 5 Beam Angle LUX 0 0929 FC Photometric Beam Angle Data ø 0 54 ø 1 77 ø 1 06 ø 3 48 Beam Diameter m ft ø 0 8 ø 2 62 0m 2 5 10m 32 8ft FC LUX 163200 72000 39600 20m 65 6ft 15m 49 2ft DMX CHANNELS 9 10 0 255 0 255 0 255 0 255 0 4 5 9 10 14 15 19 20 24 25 29 30 34 35 39 40 44 45 49 50 54 55 59 60 64 65 69 70 74 75 79 80 84 85 89 90 94 95 99 ...

Page 7: ... including amongst others calculating working load limits a fine knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Be sure to complete all rigging and installation procedures before connecting the mai...

Page 8: ... Turn Quick Lock Fasteners 1 4 Turn 1 4 Turn 08 Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below DMX 512 connecti...