T*AP
27
set up GUI – INTERFACES – (SDI I/O Interface) Status
This pan shows the status of the SDI interface (if one is installed) :
Video Standard
display of the video standard detected by the SDI input.
SDI Bypass
turns yellow if the SDI bypass function is activated.
Relay Bypass
turns yellow if the power fail relay is deactivated manually.
Test Generator Active
turns yellow if the Generator is turned on.
Video Delay Enabled
turns green if the video delay is activated.
VANC Metadata
turns green if Dolby metadata is present in the input SDI stream.
De-Embedder
VANC Metadata
turns green if VANC embedder is enabled
Embedder
De-Embedder Audio Status is grey if no audio is present
turns green if PCM audio is embedded
turns yellow if a non audio signal is present, an additional label shows
the kind of signal if it is possible to gather the information.
De-Embedder VANC
shows which SDID was found and gives the operator an indication
Metadata
which audio signals are related to that SDID.
See SMPTE 2020 for details.
ARIB B39
meta information standard
Data Available
turns green if ARIB B-39 meta information are detected
Block Error
turns red if an error has been detected
Audio Mode
see ARIB Japanese standard "Structure of Inter-Stationary Control
Data Conveyed by Ancillary Data Packets"
http://www.arib.or.jp/english/html/overview/doc/2-STD-B39v1_2.pdf