Jünger Audio-Studiotechnik GmbH
page
5
The signal available at these outputs is determined by the set up software :
The
Setup software
is an important part of the system because it allows for offline configuration of the MIX4
to fit it in almost every production environment from
Edit Workstation
to
On Air
. It serves for general
settings a user is not allowed to change from the desktop remote.
For remote control purposes the MIX4 is equipped with
8 tally outputs
and
6 GPI inputs
with TTL levels.
Their functions will be set by Setup software as well.
In addition, a
TCP/IP
over
Ethernet
interface allows the remote control of external routers via TCP/IP as well
as the centralized use of the
setup software
and the
operator/preset/backup/restore tool
over the
network.
There is also a serial interface for connection to a PC via RS 232 that serves for configuration of the MIX4.
This interface may also be used in RS 422 mode.
Ethernet
audio sync
TCP/ IP
6 x GPI
8 x Tally
power
remote connector
sync in
CAN bus
s y
s t e m
c o
n t
r o
l
l
e r
serial
232
422
optional
video sync
WC out
Firmware updates and the initial IP configuration are only possible via RS232 interface.