Jünger Audio-Studiotechnik GmbH
page
18
Compilation of the DSP processing sections and their parameters as well as their displays:
Channel-strip
Display
1
st
line Display
2
nd
line
A
Selection of the
DSP section :
N
(0 to 7)
Gain reduction
DSP
section
0=
PHASE
, 1=
LOWCUT
2=
EQ1
, 3=
EQ2
, 4=
EQ3
(see
display)
5=
DE-ESSER,
6=
EXPANDER
7=
COMPRESS
B
First parameter of the section
N.1
parameter name
parameter value
C
Second parameter of the section
N.2
parameter name
parameter value
D
Third parameter of the section
N.3
parameter name
parameter value
The table compiles the parameters and their setting range of the individual sections:
# Name
Value Range
Description
0
LEFT plus / minus
For stereo sources only L (plus/minus)
1
FREQ OFF, 40, 60, 80, 100, 120 Hz
High pass filter
2.1
FREQ 50 ... 500 Hz
in 5 Hz steps
EQ1 mid frequencies
500 Hz ... 5 kHz
in 50 Hz steps
EQ1 mid frequencies
5 kHz ... 15 kHz
in 500 Hz steps
EQ1 mid frequencies
2.2
Q LS, HS, 0.5 ... 8
in 0.5 unit steps
EQ1 type: LS=Low Shelf, HS=High Shelf, Q
2.3
RANGE
-15 ... 0 ... 15
In 1 dB steps
EQ1 attenuation / amplification
3.1
FREQ 50 Hz ... 500 Hz
in 5 Hz steps
EQ2 mid frequencies
500 Hz ... 5 kHz
in 50 Hz steps
EQ2 mid frequencies
5 kHz ... 15 kHz
in 500 Hz steps
EQ2 mid frequencies
3.2
Q LS, HS, 0.5 ... 8
in 0.5 unit steps
EQ2 type: LS=Low Shelf, HS=High Shelf, Q
3.3
RANGE -15 ... 0 ... 15
In 1 dB steps
EQ2 attenuation / amplification
4.1
FREQ 50 Hz ... 500 Hz
in 5 Hz steps
EQ3 mid frequencies
500 Hz ... 5 kHz
in 50 Hz steps
EQ3 mid frequencies
5 kHz ... 15 kHz
in 500 Hz steps
EQ3 mid frequencies
4.2
Q LS, HS, 0.5 ... 8
in 0.5 unit steps
EQ3 type: LS=Low Shelf, HS=High Shelf, Q
4.3
RANGE -15 ... 0 ... 15
In 1 dB steps
EQ3 attenuation / amplification
5.1
TYPE FEM, MAL, 1 ... 14
In 1 unit steps
De-esser frequency
5.2
RANGE 0 ... –20
In 1 dB steps
Working depth of the de-esser
6.1
THRESH OFF, -60 ... –20 dB
in 2 dB steps
Expander threshold value
6.2
RANGE -40 .... 0 dB
In 1 dB steps
Expander range
6.3
ATTACK 0.2, 0.3, 0.4, 0.5, 0.7, 1.0, 1.5, 2.0, 3.0, 4.0
Expander response time
7.1 COMP RAT OFF/ 1: 1.3, 1.6, 2.0, 3.0, 4.0
Compressor ratio
7.2 COMP RNG 0 ... 15
In 1 dB steps
Compressor amplification
7.3 COMP PRO 1 .... 9
in 1 unit steps
Processing parameters of the compressors