C8000
Frame Controller
C8702
digital audio
modular
processing system
Page 10/23
* If the PC is part of a MS Domain, you must check if the LAN settings are correct. If you have
configured your IE settings manually you must disable “Automatically detect settings”. Otherwise
it could happen that your settings are overwritten automatically at next reboot.
* You must declare the browser as an exception for the
Windows
®
Firewall
in order to maintain
proper
UDP
data transfer from and to the
JAVA Web Start
application. If you see security
issues for your system you may use the
METERING
configuration (see further below) to limit the
UDP
port numbers instead of making an exception for all incoming network connections.
Setting of frame information
The
Frame Name
and the
Frame Location
as well as the
System Contact
are used by the
SNMP
sysObject
OIDs (Object Identifier).
Activation of the security feature
The web interface of
Junger Audio
units offers a two tier
security schema
.
* Operators
can view everything and load presets.
* Administrators
can set up C8k frames including their modules.
They are allowed to change parameters and write presets.
You must check
“Password checking enabled”
to activate this feature, you will be notified about the
default settings:
If you click
<OK>
the Frame Controller will close all open sessions and you must log in again as user
"admin"
with the default password
"admin".
Now you may change passwords for both the admin and the operator: