4. OPERATION
Selection of digital signal input
INPUT
selection of digital signal input
(SDI is for SDI-version available only!)
Selection of sync signal input
SYNC
selection of sync-signal input
1/2
unit is synchronized with AES input
channel 1/2 (AES 48kHz)
EXT
unit is synchronized with AES input
signal at external sync input
VIDEO unit is locked to video signal at video
input
(with
48kHz)
SDI
unit is locked to SDI signal at SDI
input
(with
48kHz)
Note: SDI sync is available only if SDI input is active! If SDI sync is selected
only the SDI input LED lits. All LED’s in sync display are switched off!
All adjusted parameters of Ø-REV, MONO, INPUT GAIN,
MATRIX and OUTPUT GAIN can be stored into presets.
Recall of presets
preset buttons
1...4
recall of preset 1...4
Storage of presets
preset buttons
1...4
after appr. 3 sec. of pushing continously a
preset button all current adjustments will be
stored into this preset, yellow LED blinks
two
times.
Note: All former stored preset values are overwritten at the
moment of new storage into this preset! Just as after
initialization of the unit all presets are overwritten with factory
setups.
The MONO function is adding together both input channels 1/2 or
3/4 and distributes the mix signal to both channels. There is no
level reduction or correction included!
4.1
MODE
push
push
4.2
RECALLING AND
STORING OF
PRESETS
push
push
+hold
4.3
MONO
operation manual b40, chapter 4 -Operation- page 4-2