3. INSTALLATION

 

 

Operation manual b40, chapter 3 -installation-   page 3-1

INSTALLATION

 

 
 
 
 
 
 
 
 
 
 
 

3.1

 

UNPACK THE UNIT 
 
 

 
 
3.2

 

POWER SUPPLY 

3

 
 
 
 
 

 
 
 
 
The digital audio toolbox b40 was carefully packed in the factory 
and the packaging was designed to protect the equipment from 
rough handling. Please examine carefully the packaging and its 
contents for any signs of physical damage, which may have 
occured in transit. 
 
 
 
The digital audio toolbox b40 is a device under the safety 
category 

Schutzklasse 1

 in keeping with the VDE 0804 

standards and may only used with power supply installations 
built according to regulations. 
Check the voltage details printed at the rear panel are the same 
as your local mains electricity supply. 
  
 
The digital audio toolbox b40 is equipped with standard 
connectors (see also chapter 3). 
Before connecting the digital audio toolbox b40 switch the power 
off at all connected units. 
 
 
The digital audio toolbox b40 is made as standard 19“ unit (EIA 
format). It occupies 1 RU (44 mm height) space in a rack.  
Please allow at least addititonal 3“ depth for the connectors on 
the rear panel.  
When installing the unit in a 19“ rack the rear side of the unit 
needs some support, especially for mounting in flight cases. 
 
 
The digital audio toolbox b40 should not be installed near units 
which produce strong magnetic fields or extreme heat. Do not 
install the filter processor directly above or below power 
amplifiers. 
If, during operation, the sound is interrupted or displays no longer 
illuminate, or if abnormal odor or smoke is detected immediately 
disconnect the power cord plug and contact your dealer or 
Jünger Audio. 

3.3

 

CONNECTIONS

 

3.4

 

RACK MOUNTING

 

3.5

 

OPERATION 
SAFETY

 

 
 
 

Summary of Contents for b40

Page 1: ...DIGITAL AUDIO TOOLBOX model b40 operations manual rev 3 1 Justus von Liebig Stra e 7 12489 Berlin Germany Telefon 030 67 77 21 0 Fax 030 67 77 21 46 www junger audio com...

Page 2: ...channel Digital Audio Toolbox b40 Not only you have aquired the latest generation of digital dynamic range processing but also a piece of equipment which is unique in its design and specification 0 P...

Page 3: ...3 3 3 3 3 4 3 5 3 6 3 1 Unpack the unit 3 2 Power supply 3 3 Connections 3 4 Rack mounting 3 5 Operation safety 3 6 Synchronization of digital output 3 7 Remote Control 3 7 1 GPI Remote Control 3 7 2...

Page 4: ...2 Error messages and trouble shooting 5 3 Initialization the unit 6 1 6 1 6 1 6 3 7 1 8 1 6 Application notes 6 1 B40 series with SDI interface 6 2 Basic working modes with SDI 6 3 Remote control wit...

Page 5: ...panel b40 INPUT selection of digital input SYNC selection of sync input PRESET 1 4 storage and recall of presets 1 4 REV 180 phase reverse for ch1 2 or 3 4 MONO mono switching of ch1 2 or ch3 4 CH 1...

Page 6: ...e 2 2 INPUT 1 4 selection of input channel matrix and then OUTPUT 1 4 selection of output channel to set or reset connecting points of the matrix output gain CH 1 4 selection push and adjustment turn...

Page 7: ...AES 3 format 75 Ohm unbal connector BNC socket VIDEO input for video sync signal blackburst 75 Ohm unbal connector BNC socket SDI IN OUT only for SDI Version Input output for serial digital video ITU...

Page 8: ...erial remote interface Front panel is locked Note DISABLE is only activated if serial remote control is connected ADDR Selection of the device address for serial remote 16 device addresses selectable...

Page 9: ...jumper J1 on main board of the unit The 4 channel processors of b40 series fitted with SDI interface are compatibel with the standard SMPTE 272M AB They support 48 kHz synchronous audio sampling with...

Page 10: ...ing all data of this group if it was already existing necessary if a new group should be embedded and if audio in other groups was embedded previously is matching ideally the structure which was gener...

Page 11: ...40 is equipped with standard connectors see also chapter 3 Before connecting the digital audio toolbox b40 switch the power off at all connected units The digital audio toolbox b40 is made as standard...

Page 12: ...tically The digital output signal can be clocked with the following clock frequencies CH 1 2 locks with the clock frequency of the input signal at digital input CH 1 2 AES EBU EXT SYNC locks with the...

Page 13: ...e Logic I O Functions 1 PRESET1 L I call preset1 2 PRESET2 L I call preset2 3 PRESET3 L I call preset3 4 PRESET4 L I call preset4 5 FACTORY PRESET L I call factory preset not alterable 6 BYPASS L I by...

Page 14: ...Logic I O Functions 1 PRESET1 H O preset1 recalled 2 PRESET2 H O preset2 recalled 3 PRESET3 H O preset3 recalled 4 PRESET4 H O preset4 recalled 5 OVERLOAD H O overlevel at digital output ch1 4 6 BYPA...

Page 15: ...st be connected on both ends 5 1 9 6 REMOTE IN Pin Signal name Functions 1 DSR out Data set ready 2 DSR out 3 SENSE in Interrogation Remote 4 RXD out Receive data 5 RXD out 6 DTR in Data terminal read...

Page 16: ...3 INSTALLATION 3 8 BLOCK DIAGRAM Operation manual b40 chapter 3 installation page 3 6...

Page 17: ...is made by adjustment of various parameters and settings The description is made related to the functional blocks on the front panel 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 mode recalling and storing of...

Page 18: ...parameters of REV MONO INPUT GAIN MATRIX and OUTPUT GAIN can be stored into presets Recall of presets preset buttons 1 4 recall of preset 1 4 Storage of presets preset buttons 1 4 after appr 3 sec of...

Page 19: ...the OUTPUT buttons 1 selection of input channel by pushing related INPUT button 2 selection of requested output channel by pushing related OUTPUT button This procedure is to repeat up to all necessary...

Page 20: ...level at the output occurs if digital audio samples at the maximum permissable positive or negative sample value occur at the digital output then the red clip LED at the extreme right hand end of the...

Page 21: ...SAGES AND TROUBLE SHOOTING display error message remedies NO SYNC no sync at sync input connect the sync input selectable in SYNC field with valid input signal CH 1 2 sync on DIGITAL IN CH 1 2 EXT syn...

Page 22: ...restarted Any button is to be held pressed in order to initialize the device during switch on of the device until the program started To the start of the program and at the completion of the displays...

Page 23: ...is Group 1 with 48 kHz synchronous sampling Synchronous means that the audio clock is genlocked to the associated video Each channel can have up to 20 bits of resolution per audio sample The 4 channe...

Page 24: ...6 APPLICATION NOTES operation manual b40 chapter 6 Application notes page 6 2...

Page 25: ...e button only features of brc4x universal remote control panel RS 422 remote operation of several units up to 16 devices various models of b40series together are possible self detecting remote system...

Page 26: ...75 Ohm coaxial data rate 270 Mb s 525 625 Line rate format serial digital component video 4 2 2 with embedded audio ITU R BT 601 SMPTE 272M A level 800 mV 10 equalisation appr 180 m Belden 8281 audio...

Page 27: ...rallel remote level TTL connector 9 pin SUB D female Tally Out level TTL max 25mA connector 9 pin SUB D male GENERAL power consumption appr 15 VA dimensions 19 1 RU 250 mm depth weight appr 5 kg optio...

Page 28: ...RRANTY AND SERVICE INFORMATION 8 J NGER AUDIO grants a two year warranty on the 4 channel digital audio toolbox b40 If the unit has to be serviced please send it ideally in the original box to J NGER...

Reviews: