5. OPERATION
COMPRESSOR MENU (compressor button)
5.5
Compressor menu shows compressor settings.
Adjustments are made by pushing and turning SELECT knob (see 5.1).
CMP RATIO RANGE PRO
ON 1.8 6 5
CMP:
compressor
on/off
(by pushing SELECT knob, green LED in button
lits if function block is switched on)
RATIO:
compressor ratio 1.0:1 ...4.0:1 in 13 steps
RANGE:
compression range (maximum compression
gain) 0 ... +15 dB
PRO:
adjustment of processing characteristic
(range of time constant values for adaptive
processing) for optimum processing results
from 0 (very fast) to 9 (very slow)
>
see
application
notes!
LIMITER MENU (limiter button)
5.6
Limiter menu shows limiter settings.
Adjustments are made by pushing and turning SELECT knob (see 5.1).
LIM THRS PRO
ON -9.0 1
LIM:
limiter
on/off
(by pushing SELECT knob, green LED in button
lits if function block is switched on)
THRS:
limiter threshold level -20 ... 0 dBFS
PRO:
adjustment of processing characteristic
(range of time constant values for adaptive
processing) for optimum processing results
from 0 (very fast) to 9 (very slow)
> see application notes!
EXPANDER MENU (expander button)
5.7
Expander menu shows expander settings.
Adjustments are made by pushing and turning SELECT knob (see 5.1).
EXP THRSH RANGE REL
ON -32 31 2.0
EXP:
expander
on/off
(by pushing SELECT knob, green LED in button
lits if function block is switched on)
THRSH:
expander threshold -60...-20dBFS
RANGE:
expander range 0...+40 dB, GATE
REL:
expander release time 0.2 ... 4 sec