![Jung TK AS AL 114 Product Information Download Page 21](http://html1.mh-extra.com/html/jung/tk-as-al-114/tk-as-al-114_product-information_2031563021.webp)
21
Labelling the nameplate
Use the
JUNG labeling tool
to label the nameplates of your outdoor stations. You will find it
at the following Internet address:
www.jung-label.de.
1.
In the "Template" field, select the ref.-number of your outdoor station,
e.g. TK AS AL 114 A WW. Arrange the template to suit your requirements.
2.
Using a laser printer, print the nameplates on the supplied special foil,
Ref. No.: TK 60 FO.
3.
Insert the foil into the nameplate.
!
Use only the supplied foil to label the nameplates! Jung Ref.-No.: TK 60 FO.
Fault identification, indication and querying
•
Faults are signalled visually and acoustically (single fault tone and continuous flashing
of the light strip).
•
The fault type can be queried by pressing any bell button, the fault tone is sounded
again.
Fault sources
Fault sources
Nameplate illumi-
nation indication
Fault tone Elimination
No EEPROM
Insert EEPROM,
switch mains voltage on again!
a and P wires interchanged
Exchange a and P wires, device back to
idle mode in a few seconds
"a" wire not connected
Connect a wire, device back to idle
mode in a few seconds
Button sticks
(pressed > approx. 20 s)
Outdoor station in
fault mode: flashes
Release button, device back to idle
mode in a few seconds