Jung FMJ50700UP Operating Instructions Manual Download Page 9

Priority, restraint

0...4
Basic setting: 2

Specifies the priority for
recalling and removing a
scene of type Restraint for the
channel.

Activate force operation blind
position

0 ... 100 %
Basic setting: 0 %

Defines the behaviour of the
output on activating the forced
operation.

Recall forced operation slat
position

0 ... 100 %
Basic setting: 0 %

Defines the slat position of the
output on activating forced
operation. Only visible when
the Venetian blind operating
mode is set.

Deactivate force operation
blind position

0 ... 100 %
Basic setting: 0 %

Defines the behaviour of the
output on deactivating the
forced operation. Only visible
when the priority for the forced
operation is 0.

Deacitvate forced operation
slat position

0 ... 100 %
Basic setting: 0 %

Defines the slat position of the
output on deactivating forced
operation. Only visible when
the priority for the forced
operation is 0 and the
Venetian blind operating mode
is set.

Priority, wind alarm

0...4
Basic setting: 3

Specifies the priority for
recalling and removing a
scene of type Wind alarm for
the channel.

Activate wind alarm blind
position

0 ... 100 %
Basic setting: 0 %

Defines the behaviour of the
output on activating the wind
alarm. 

Recall wind alarm slat position 0 ... 100 %

Basic setting: 0 %

Defines the slat position of the
output on activating the wind
alarm. Only visible when the
Venetian blind operating mode
is set.

Deactivate wind alarm blind
position

0 ... 100 %
Basic setting: 0 %

Defines the behaviour of the
output on deactivating the
wind alarm. Only visible when
the priority for the wind alarm
is 0.

Deacitvate wind alarm slat
position

0 ... 100 %
Basic setting: 0 %

Defines the slat position of the
output on deactivating the
wind alarm. Only visible when
the priority for the wind alarm
is 0 and the Venetian blind
operating mode is set.

Priority, sun protection

0...4
Basic setting: 0

Specifies the priority for
recalling and removing a
scene of type Sun protection
for the channel.

Activate sun protection blind
position

0 ... 100 %
Basic setting: 100 %

Defines the behaviour of the
output on activating the sun
protection.

9/11

82581443
J0082581443

24.03.2017

eNet radio blinds actuator 1-gang mini

Summary of Contents for FMJ50700UP

Page 1: ...ctions of the manufacturers and to use a cut off relay if necessary The motors may be destroyed Risk of injury Use the device only for controlling Venetian blind and roller shutter motors or awnings D...

Page 2: ...signalling could vary from what is described here Supplementary functions with eNet Server Fully encrypted radio transmission AES CCM from eNet Server software version 2 0 Update of the device softwa...

Page 3: ...termine slat time O Blind operating mode P Operating mode rolling shutter awning If the operating mode switch is turned from the position PC to another operating mode the parameters are set to the def...

Page 4: ...running time for blind The operating mode switch figure 3 is in the Venetian blind O or rolling shutter P position o Turn the operating mode switch 1 to the I t position until the blind shutter reach...

Page 5: ...radio transmitter all connections must be disconnected individually Resetting the device to the factory setting All connections to radio transmitters are disconnected and parameters are reset to defau...

Page 6: ...asic setting Roller shutter Roller shutter A rolling shutter or an awning is controlled for which the Fabric stretching function is required Venetian blind A Venetian blind is controlled Awning An awn...

Page 7: ...Roller shutter See Device and channels Manual commissioning On Off Basic setting On Blocks manual commissioning for the device channel In the Off setting the device cannot be reset to the factory set...

Page 8: ...lues On Off Basic setting On Disables the saving of the current Venetian blind position as scene value in an actuator for a command via a transmitter Priority lock out protection 0 4 Basic setting 1 S...

Page 9: ...the priority for recalling and removing a scene of type Wind alarm for the channel Activate wind alarm blind position 0 100 Basic setting 0 Defines the behaviour of the output on activating the wind a...

Page 10: ...ght slat position 0 100 Basic setting 100 Defines the slat position of the output on activating the twilight function Only visible when the Venetian blind operating mode is set Deactivate twilight bli...

Page 11: ...by declares that the radio system type Art No FMJ50700UP corresponds to the directive 2014 53 EU You can find the full article number on the device The complete text of the EU Declaration of Conformit...

Reviews: