![Jung FMJ50700UP Operating Instructions Manual Download Page 9](http://html1.mh-extra.com/html/jung/fmj50700up/fmj50700up_operating-instructions-manual_2031661009.webp)
Priority, restraint
0...4
Basic setting: 2
Specifies the priority for
recalling and removing a
scene of type Restraint for the
channel.
Activate force operation blind
position
0 ... 100 %
Basic setting: 0 %
Defines the behaviour of the
output on activating the forced
operation.
Recall forced operation slat
position
0 ... 100 %
Basic setting: 0 %
Defines the slat position of the
output on activating forced
operation. Only visible when
the Venetian blind operating
mode is set.
Deactivate force operation
blind position
0 ... 100 %
Basic setting: 0 %
Defines the behaviour of the
output on deactivating the
forced operation. Only visible
when the priority for the forced
operation is 0.
Deacitvate forced operation
slat position
0 ... 100 %
Basic setting: 0 %
Defines the slat position of the
output on deactivating forced
operation. Only visible when
the priority for the forced
operation is 0 and the
Venetian blind operating mode
is set.
Priority, wind alarm
0...4
Basic setting: 3
Specifies the priority for
recalling and removing a
scene of type Wind alarm for
the channel.
Activate wind alarm blind
position
0 ... 100 %
Basic setting: 0 %
Defines the behaviour of the
output on activating the wind
alarm.
Recall wind alarm slat position 0 ... 100 %
Basic setting: 0 %
Defines the slat position of the
output on activating the wind
alarm. Only visible when the
Venetian blind operating mode
is set.
Deactivate wind alarm blind
position
0 ... 100 %
Basic setting: 0 %
Defines the behaviour of the
output on deactivating the
wind alarm. Only visible when
the priority for the wind alarm
is 0.
Deacitvate wind alarm slat
position
0 ... 100 %
Basic setting: 0 %
Defines the slat position of the
output on deactivating the
wind alarm. Only visible when
the priority for the wind alarm
is 0 and the Venetian blind
operating mode is set.
Priority, sun protection
0...4
Basic setting: 0
Specifies the priority for
recalling and removing a
scene of type Sun protection
for the channel.
Activate sun protection blind
position
0 ... 100 %
Basic setting: 100 %
Defines the behaviour of the
output on activating the sun
protection.
9/11
82581443
J0082581443
24.03.2017
eNet radio blinds actuator 1-gang mini