Invert movement direction
On, Off
Basic setting: Off
Inverts the activation of the
relay outputs. During inverted
operation, the relay outputs
"Up" and "Down" should be
activated in reverse. This is
required, for example, for
controlling skylights.
Behaviour on voltage return
No change
Configured value
Basic setting: No change
Defines the behaviour of the
output after voltage return.
RMD design: Bus voltage
return
Configured venetian blind
position
0 ... 100 %
Basic setting: 0 %
If the value "Configured
position" is entered for the
parameter "Behaviour after
voltage return", then the
blind/shutter position set here
is approached.
Configured slat position
0 ... 100 %
Basic setting: 0 %
If the value "Configured
position" is entered for the
parameter "Behaviour after
voltage return", then the slat
position set here is
approached.
Behaviour after the end of the
disabling function
no change
Last value
Down
up
Basic setting: No change
Behaviour of the output when
a block is removed.
Manual saving of the scene
values
On, Off
Basic setting: On
Disables the saving of the
current Venetian blind position
as scene value in an actuator
for a command via a
transmitter.
Priority, lock-out protection
0...4
Basic setting: 1
Specifies the priority for
recalling and removing a
scene of type Lock-out
protection for the channel.
Activate lock-out protection
blind position
0 ... 100 %
Basic setting: 0 %
Defines the behaviour of the
output on activating the lock-
out protection.
Activate lock-out protection
slat position
0 ... 100 %
Basic setting: 0 %
Defines the slat position of the
output on activating the lock-
out protection. Only visible
when the Venetian blind
operating mode is set.
Deactivate lock-out protection
blind position
0 ... 100 %
Basic setting: 0 %
Defines the behaviour of the
output on deactivating the
lock-out protection. Only
visible when the priority for the
lock-out protection is 0.
Deacitvate lock-out protection
slat position
0 ... 100 %
Basic setting: 0 %
Defines the behaviour of the
output on deactivating the
lock-out protection. Only
visible when the priority for
lock-out protection is 0 and the
Venetian blind operating mode
is set.
8/11
82581443
J0082581443
24.03.2017
eNet radio blinds actuator 1-gang mini