Jung FMJ50700UP Operating Instructions Manual Download Page 8

Invert movement direction

On, Off
Basic setting: Off

Inverts the activation of the
relay outputs. During inverted
operation, the relay outputs
"Up" and "Down" should be
activated in reverse. This is
required, for example, for
controlling skylights.

Behaviour on voltage return

No change
Configured value
Basic setting: No change

Defines the behaviour of the
output after voltage return.
RMD design: Bus voltage
return

Configured venetian blind
position

0 ... 100 %
Basic setting: 0 %

If the value "Configured
position" is entered for the
parameter "Behaviour after
voltage return", then the
blind/shutter position set here
is approached.

Configured slat position

0 ... 100 %
Basic setting: 0 %

If the value "Configured
position" is entered for the
parameter "Behaviour after
voltage return", then the slat
position set here is
approached.

Behaviour after the end of the
disabling function

no change
Last value
Down
up
Basic setting: No change

Behaviour of the output when
a block is removed.

Manual saving of the scene
values

On, Off
Basic setting: On

Disables the saving of the
current Venetian blind position
as scene value in an actuator
for a command via a
transmitter.

Priority, lock-out protection

0...4
Basic setting: 1

Specifies the priority for
recalling and removing a
scene of type Lock-out
protection for the channel.

Activate lock-out protection
blind position

0 ... 100 %
Basic setting: 0 %

Defines the behaviour of the
output on activating the lock-
out protection.

Activate lock-out protection
slat position

0 ... 100 %
Basic setting: 0 %

Defines the slat position of the
output on activating the lock-
out protection. Only visible
when the Venetian blind
operating mode is set.

Deactivate lock-out protection
blind position

0 ... 100 %
Basic setting: 0 %

Defines the behaviour of the
output on deactivating the
lock-out protection. Only
visible when the priority for the
lock-out protection is 0.

Deacitvate lock-out protection
slat position

0 ... 100 %
Basic setting: 0 %

Defines the behaviour of the
output on deactivating the
lock-out protection. Only
visible when the priority for
lock-out protection is 0 and the
Venetian blind operating mode
is set.

8/11

82581443
J0082581443

24.03.2017

eNet radio blinds actuator 1-gang mini

Summary of Contents for FMJ50700UP

Page 1: ...ctions of the manufacturers and to use a cut off relay if necessary The motors may be destroyed Risk of injury Use the device only for controlling Venetian blind and roller shutter motors or awnings D...

Page 2: ...signalling could vary from what is described here Supplementary functions with eNet Server Fully encrypted radio transmission AES CCM from eNet Server software version 2 0 Update of the device softwa...

Page 3: ...termine slat time O Blind operating mode P Operating mode rolling shutter awning If the operating mode switch is turned from the position PC to another operating mode the parameters are set to the def...

Page 4: ...running time for blind The operating mode switch figure 3 is in the Venetian blind O or rolling shutter P position o Turn the operating mode switch 1 to the I t position until the blind shutter reach...

Page 5: ...radio transmitter all connections must be disconnected individually Resetting the device to the factory setting All connections to radio transmitters are disconnected and parameters are reset to defau...

Page 6: ...asic setting Roller shutter Roller shutter A rolling shutter or an awning is controlled for which the Fabric stretching function is required Venetian blind A Venetian blind is controlled Awning An awn...

Page 7: ...Roller shutter See Device and channels Manual commissioning On Off Basic setting On Blocks manual commissioning for the device channel In the Off setting the device cannot be reset to the factory set...

Page 8: ...lues On Off Basic setting On Disables the saving of the current Venetian blind position as scene value in an actuator for a command via a transmitter Priority lock out protection 0 4 Basic setting 1 S...

Page 9: ...the priority for recalling and removing a scene of type Wind alarm for the channel Activate wind alarm blind position 0 100 Basic setting 0 Defines the behaviour of the output on activating the wind a...

Page 10: ...ght slat position 0 100 Basic setting 100 Defines the slat position of the output on activating the twilight function Only visible when the Venetian blind operating mode is set Deactivate twilight bli...

Page 11: ...by declares that the radio system type Art No FMJ50700UP corresponds to the directive 2014 53 EU You can find the full article number on the device The complete text of the EU Declaration of Conformit...

Reviews: