The blind/shutter starts.
The status LED flashes after 4 seconds and the blind/shutter stops. The actuator is in
programming mode for approx. 1 minute.

o

Switch radio transmitter to programming mode (see radio transmitter instructions).

o

Trigger telegram on the radio transmitter.
The status LED lights up for 5 seconds.
The actuator is connected to the radio transmitter. The actuator and radio transmitter exit
the programming mode automatically.

i

If the status LED of the actuator flashes 3 times at 1-second intervals for approx. 5
seconds, then the programming operation was not successful. All the memory locations in
the actuator or radio transmitter are occupied.

i

Scene buttons must be connected separately.

 Disconnecting connection to a radio transmitter

o

Carry out the same steps as when connecting (see Connecting actuator to radio
transmitters). 
The status LED of the actuator flashes quickly for 5 seconds. 
The actuator is disconnected from the radio transmitter. The actuator and radio transmitter
exit the programming mode automatically.

i

If there several connections or scene buttons for a radio transmitter, all connections must
be disconnected individually.

Resetting the device to the factory setting

All connections to radio transmitters are disconnected and parameters are reset to default
setting. If the operating mode switch is on 

PC

, the rolling shutter operating mode is set.

i

The connections in the radio transmitters are preserved and must be deleted separately.

Load is switched off.

o

Press the 

Prog

 button for at least 20 seconds.

The blind/shutter starts.
The status LED flashes after 4 seconds and the blind/shutter stops. The status LED flashes
faster after 20 seconds.

o

Release 

Prog

 button and press briefly once again within 10 seconds.

The status LED flashes more slowly for approx. 5 seconds.
The device is reset to default setting.

6 Appendix

6.1 Technical data

Rated voltage

AC 230 V ~

Mains frequency

50 / 60 Hz

Ambient temperature

-25 ... +70 °C

Minimum actuation time in operating mode
Venetian blind

0.1 s

Roller shutter

0.3 s

Minimum switching current AC

100 mA

Contact type

µ

Standby power

max. 0.5 W

Running time

1 ... 600 s

Running time default setting

120 sec

Slat adjusting time

0 ... 10 s

Connected load
Motors

1000 W

Connection
single stranded

0.75 ... 4 mm²

Finely stranded with conductor sleeve

0.75 ... 2.5 mm²

5/11

82581443
J0082581443

24.03.2017

eNet radio blinds actuator 1-gang mini

Summary of Contents for FMJ50700UP

Page 1: ...ctions of the manufacturers and to use a cut off relay if necessary The motors may be destroyed Risk of injury Use the device only for controlling Venetian blind and roller shutter motors or awnings D...

Page 2: ...signalling could vary from what is described here Supplementary functions with eNet Server Fully encrypted radio transmission AES CCM from eNet Server software version 2 0 Update of the device softwa...

Page 3: ...termine slat time O Blind operating mode P Operating mode rolling shutter awning If the operating mode switch is turned from the position PC to another operating mode the parameters are set to the def...

Page 4: ...running time for blind The operating mode switch figure 3 is in the Venetian blind O or rolling shutter P position o Turn the operating mode switch 1 to the I t position until the blind shutter reach...

Page 5: ...radio transmitter all connections must be disconnected individually Resetting the device to the factory setting All connections to radio transmitters are disconnected and parameters are reset to defau...

Page 6: ...asic setting Roller shutter Roller shutter A rolling shutter or an awning is controlled for which the Fabric stretching function is required Venetian blind A Venetian blind is controlled Awning An awn...

Page 7: ...Roller shutter See Device and channels Manual commissioning On Off Basic setting On Blocks manual commissioning for the device channel In the Off setting the device cannot be reset to the factory set...

Page 8: ...lues On Off Basic setting On Disables the saving of the current Venetian blind position as scene value in an actuator for a command via a transmitter Priority lock out protection 0 4 Basic setting 1 S...

Page 9: ...the priority for recalling and removing a scene of type Wind alarm for the channel Activate wind alarm blind position 0 100 Basic setting 0 Defines the behaviour of the output on activating the wind a...

Page 10: ...ght slat position 0 100 Basic setting 100 Defines the slat position of the output on activating the twilight function Only visible when the Venetian blind operating mode is set Deactivate twilight bli...

Page 11: ...by declares that the radio system type Art No FMJ50700UP corresponds to the directive 2014 53 EU You can find the full article number on the device The complete text of the EU Declaration of Conformit...

Reviews: