Jung FA 26 UP Operating Instructions Manual Download Page 6

Push the single-stranded cable into the round opening on the installation side up to the 
stop (figure 7). 

5.2 Commissioning 

Observe the instructions for the radio transmitter. 

DANGER! 
Electrical shock when live parts are touched. 
Electrical shocks can be fatal. 
During commissioning, cover the parts carrying voltage on radio transmitters 
and actuators and in their surrounding area. 

Teaching a radio transmitter 

If all memory slots of an output are occupied, a radio transmitter which has already been 
taught must first be deleted. To do this, delete all taught channels and light scenes of the 
radio transmitter individually. 

The distance between the receiver and the radio transmitter is from 0.5 m to 5 m. 
Load is switched off. 

Press the programming button for approx. 4 seconds. 
LED flashes red Device switches the connected loads off and is in programming mode for 
output A for approx. 1 minute. 

To enter the programming mode for output B, press programming button again for 
4 seconds. LED flashes green 

Trigger teach telegram on radio transmitter, see instructions for radio transmitter. 
LED lights up red for output A or green for output B. 
The radio transmitter has been taught. 

Press the programming button briefly. 
The load switches on. The device is in operating mode. 

The programming mode is exited automatically after about 1 minute. 

Only switch actuator: When a radio transmitter is taught, All On and All Off buttons that are 
present are automatically also taught. 

Only switch actuator: Teach light scene push-buttons separately. 

 Deleting radio transmitters individually 

Teach the radio transmitter to be deleted again (see Teaching the radio transmitter). 
LED flashes quickly in the colour corresponding to the output. The radio transmitter has 
been deleted. 

If several channels or light scenes of a radio transmitter have been taught, they all must be 
deleted individually. 

6 Appendix 

The icon confirms the conformity of the product to the relevant guidelines. 

6.1 Technical data 

Rated voltage 

AC 230 / 240 V ~ 

Mains frequency 

50 / 60 Hz 

Ambient temperature 

-20 ... +55 °C 

Relative humidity 

approx. 0 ... 65 % (No moisture condensation) 

Total power consumption 

max. 2300 W/VA 

Connected load per output 
Incandescent lamps 

2300 W 

HV halogen lamps 

2300 W 

6/7 

82534823 
J:0082534823 

12.02.2013 

Radio Management  

Radio actuator, 2-channel, flush-mounted 

Summary of Contents for FA 26 UP

Page 1: ...oad Danger of electric shock Device is not suitable for disconnection from supply voltage Do not use device as a venetian blind actuator Otherwise the Venetian drive motor may be destroyed The radio c...

Page 2: ...x 70 Reinforced concrete approx 30 Metal Metal grid approx 10 Rain Snow approx 1 40 Intended use Radio controlled switching of incandescent lamps fluorescent lamps HV halogen lamps and Tronic or induc...

Page 3: ...ion A radio transmitter has to be taught in order to be able to operate the device i Observe the instructions for the radio transmitter 5 Information for electrically skilled persons 5 1 Fitting and e...

Page 4: ...e figure 4 i For mounting outside of the appliance box e g baldachin luminaires ensure sufficient protection against electric shock o Switch on mains voltage Testbetrieb am Ger t The device can be sta...

Page 5: ...Figure 6 Connection of the fine wire cable o Push the terminal together on the side with the square opening and connect a fine wire cable figure 6 Figure 7 Connection of the single stranded cable 5 7...

Page 6: ...for radio transmitter LED lights up red for output A or green for output B The radio transmitter has been taught o Press the programming button briefly The load switches on The device is in operating...

Page 7: ...range Using a radio repeater The device switches the load off and cannot be switched on again Cause overheating protection has tripped Disconnect device from mains also switch associated off circuit...

Reviews: