Blue conductor (BU) - N, neutral conductor
o
Connect actuator to lamp terminals according to connection example (figure 3) (see Using
the lamp terminals).
Figure 4: Installation in appliance box
o
Insert the device in the appliance box in such a way that the programming button and the
LED are visible.
i
Lay the antenna stretched out freely if possible(figure 4).
i
For mounting outside of the appliance box, e.g. baldachin luminaires, ensure sufficient
protection against electric shock.
o
Switch on mains voltage.
Testbetrieb am Gerät
The device can be started by pressing the programming button briefly several times in
sequence, for about 1 second, see table.
Operations
Output L
A
Output L
B
LED
1 x
ON
OFF
red
2 x
OFF
ON
green
3 x
ON
ON
red/green
4 x
OFF
OFF
OFF
o
Perform commissioning.
o
Mount the cover.
4/7
82534823
J:0082534823
12.02.2013
Radio Management