background image

Contents

Unpacking Check............................................................................................1
Package Contents............................................................................................ 1
Safety Precautions...........................................................................................1
Warning............................................................................................................3
Symbols........................................................................................................... 4
Body Temperature Basics............................................................................... 6
Product Description.........................................................................................7
Features............................................................................................................8
Product structure............................................................................................. 9
Display description..........................................................................................9
Sounds and backlight instructions................................................................10
Display and Operating Instructions..............................................................11
Measuring Ear Temperature......................................................................... 17
Measuring Forehead Temperature................................................................19
Measuring Object Temperature....................................................................20
Replacing Batteries....................................................................................... 21
Cleaning and Disinfection............................................................................ 22
Maintenance.................................................................................................. 23
Troubleshooting.............................................................................................24
Specifications................................................................................................ 25
Security Class................................................................................................26
Storage and Transportation...........................................................................26
EMC Information-Guidance and Manufacture’s Declaration....................27
Warranty and After-Sale Service..................................................................32

Summary of Contents for JPD-FR410

Page 1: ...JPD FR410 Infrared Thermometer Instruction Manual Shenzhen Jumper Medical Equipment Co Ltd Manual Version 1 0 Date of Issue 2018 08 0482...

Page 2: ...ithout the prior consent of Shenzhen Jumper Medical Equipment Co Ltd All statements information and recommendations in this document are provided AS IS without warranties guarantees or representations...

Page 3: ...cklight instructions 10 Display and Operating Instructions 11 Measuring Ear Temperature 17 Measuring Forehead Temperature 19 Measuring Object Temperature 20 Replacing Batteries 21 Cleaning and Disinfe...

Page 4: ...ealer or contact Jumper directly You will need the following information when making your claim device model serial number purchase date and your contact information and address Package Contents No Na...

Page 5: ...20 minutes after you do physical exercises or get excited Clean the thermometer probe after each use Do not use the thermometer on newborns or for continuous temperature monitoring purposes Do not us...

Page 6: ...than 10 C 50 F which is beyond the operating temperature range of the thermometer Risk of pollution The user is recommended to send the overdue thermometer to local garbage disposal site or send it ba...

Page 7: ...ttery may explode Do not disassemble the thermometer or attempt to repair it Otherwise the thermometer may be damaged permanently Do not take temperature measurements on body parts other than forehead...

Page 8: ...e MDD93 42 EEC requirements Waste electrical materials should be sent to a dedicated collection point for recycling IPX0 Degree of protection against the Ingress of water Warning A personal injury or...

Page 9: ...8 0 C 97 9 F 100 4 F The normal body temperature range slightly varies with age and gender Generally newborns or children have higher body temperature than adults and adults have higher body temperatu...

Page 10: ...s of a shell an LCD a measure button a beeper an infrared temperature sensor and a Microprocessor 3 Operating principle The infrared temperature sensor collects infrared energy emitted by the eardrum...

Page 11: ...nd measurement 04 High accuracy Advanced infrared temperature sensor with high sensitivity High accuracy with automatic temperature calibration 05 Diverse functions 20 reading recalled Fever alert Swi...

Page 12: ...off the cover when measuring the ear temperature 6 Probe cover put the cover on when measuring the forehead temperature 7 Unit switch button 8 Memory button Sound switch 9 Battery cover Display descr...

Page 13: ...ect temperature 0 100 32 0 212 A long beep Orange Note When the forehead and the ear temperature is between 35 0 C 95 0 and 37 5 C 99 5 there will be a long beep and a red backlight This indicates tha...

Page 14: ...nd to power on the thermometer Press the Mode button the thermometer enters the Ear mode The symbol is displayed on the screen Switch to the adult or child measurement mode by dialing the side adult c...

Page 15: ...hermometer enters the Forehead mode The Head symbol is displayed on the screen Switch to the adult or child measurement mode by dialing the side adult child switcher according to your measurement need...

Page 16: ...d on the screen See the table in the Sounds and backlight color instructions section Out of the measuring range display In Ear mode a temperature reading of more than 42 0 C 107 6 F In Forehead mode a...

Page 17: ...be shown followed by the recorded reading Press the Memory button again for the next recorded data 2 will be shown followed by the recorded reading A maximum of 20 temperature readings can be recalle...

Page 18: ...a long beep the backlight is orange then turn red Switching between mute and un mute In the power on state press and hold the sound switch button for about 2 seconds to switch the sound on or off When...

Page 19: ...nd body temperature Body temperature contains the Forehead temperature and Ear temperature Silent the backlight is orange Switching between F C In the power off state remove the battery cover and togg...

Page 20: ...data is being read from or written to the memory or the temperature correction is not complete A long beeps the backlight is red When the battery voltage is lower than 2 5V 0 1V the low battery symbo...

Page 21: ...ring children place the switching device in the child mode and the symbol is displayed on the screen 6 Insert the temperature probe into the ear canal 7 Press and release the Measure button The ear te...

Page 22: ...3 Press the Mode button the thermometer enters the Forehead mode the Head symbol is displayed on the screen 4 When measuring adults place the switching device in the adult mode When measuring children...

Page 23: ...easure button for 1 second The temperature reading will be displayed on the screen instantly 6 If no activity is detected the thermometer will power off automatically in 10 seconds After a measurement...

Page 24: ...the thermometer for a long time because it is sensitive to the ambient temperature 4 Make sure the sense head is free of foreign matters before use 5 Make sure the forehead has no sweat and no hairs...

Page 25: ...Home use mild detergents Cleaning steps 1 Take the batteries out before cleaning 2 Clean the temperature probe with a soft cloth Clean the lens of the temperature probe with a cotton swab 3 Wipe the t...

Page 26: ...ection time is completed within 1 minute and the number of repetitions per disinfection is not more than 2 times Clean and disinfect the thermometer under the temperature of 10 40 50 104 the relative...

Page 27: ...Contact the manufacturer Er1 is displayed The ambient temperature is lower than 10 C 50 0 F or higher than 40 C 104 F Take a measurement under an ambient temperature between 10 C 50 0 F and 40 C 104 F...

Page 28: ...lay Segment LCD Measure time About 1 second Latency Time About 3 second Measuring Range Forehead mode 35 0 C 42 2 C 95 0 F 108 0 F Ear mode 35 0 C 42 0 C 95 0 F 107 6 F Object mode 0 0 C 100 0 C 32 0...

Page 29: ...t Degree of protection against electric shock Type BF applied part Degree of protection against ingress of water IPX0 Safety degree of using in flammable anesthetic gas blending with air oxygen or nit...

Page 30: ...nd manufacturer s declaration Electromagnetic emission for all equipment and systems Guidance and manufacturer s declaration Electromagnetic emission The Infrared Thermometer JPD FR410 is intended for...

Page 31: ...se in the electromagnetic environment specified below The customer or the user of the Infrared Thermometer JPD FR410 should assure that it is used in such an environment Immunity test IEC 60601 test l...

Page 32: ...PD FR410 should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Radiated RF IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz...

Page 33: ...E 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic is affected by absorption and reflection from structures objects an...

Page 34: ...d the EQUIPMENT or SYSTEM for EQUIPMENT and SYSTEMS that are not LIFE SUPPORTING The Infrared Thermometer JPD FR410 is intended for use in an electromagnetic environment in which radiated RF disturban...

Page 35: ...not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Warranty and After Sale Service The device is under warranty for on...

Page 36: ...Shenzhen Jumper Medical Equipment Co Ltd Address D Building No 71 Xintian Road Fuyong Street Baoan Shenzhen Guangdong China Tel 86 755 26696279 Fax 86 755 26852025 Website http www jumper medical com...

Reviews: