3 Operation - Configuration - Parameterization
20
3.2.7
Binary functions (binF)
The binary signals of the binary output, the limit value monitoring and the timer can be used to
trigger different functions.
The binary functions for start and abort react to the rising flank of the triggering signal, all other
binary functions are state-dependent controlled and active with "High".
ConF
->
binF
->
3.2.8
Display and operation (diSP)
Both displays and the function key can be individually adapted to the respective requirements.
ConF
->
diSP
->
Parameters
Value
Description
Binary input
bin1
0
Signal without function
1
Start self-optimization
2
Abort self-optimization
Limit value monito-
ring 1 and 2
LiI
,
Li2
3
Change to manual mode
4
Switch off controller (controller outputs inactive)
5
Switch on controller
6
Inhibit manual mode
Timer signal
tF1
7
Stop ramp/firing curve
8
Abort ramp/firing curve
9
Restart ramp, start/abort firing curve
10
Switch over from setpoint 1 to setpoint 2
11
Lock keypad
12
Inhibit parameter and configuration level,
inhibit self-optimization start
13
Switch off the display
14
Start timer
15
Abort timer
16
Stop timer
17
Start/abort timer
Parameters
Value
Description
Upper display
diSU
2
Display value for the upper display;
2 = Actual value
Ö
Ö
"Analog selector", page 15
Lower display
diSL
3
Display value for the lower display;
3 = current set point
value
Ö
"Analog selector", page 15