3 Operation and visualization
40
Status
messages
Status messages of the disk manager are displayed in the corresponding ac-
tion window. The following status messages are possible:
Status message
Description
DISKETTE UPDATED
Directly before removing the diskette from the
instrument, it is necessary to call up
Update
diskette,
so that all the measurement data up to
the time of removal are contained on the diskette.
The data not yet saved since the last automatic
save are written to diskette.
DISKETTE NOT UPDATED
An error has occurred during updating.
This message may have several causes.
Remedy:
Repeat procedure
INITIALIZING DISKETTE
The instrument recognizes when new or foreign
diskettes are inserted.
A
New or foreign diskettes are
overwritten
without
a security check.
NO DISKETTE
If there is no diskette in the instrument, the
diskette symbol flashes in the status line.
DISKETTE
WRITEPROTECTED
The inserted diskette cannot be written to
because it is write protected.
Remedy:
Remove write protection.
DISKETTE FAULTY
An error has occured while writing to diskette.
The diskette is faulty.
Remedy:
Insert new (DOS-formatted) diskette.
DISKETTE FULL
If the diskette is full, the diskette symbol flashes in
the status line. No more data are written to
diskette.
Remedy:
Insert a blank diskette before the measurement
data memory of the recorder is also full. If this is
not done, then measurement data will be lost.
PROGRAM DISKETTE
This message appears when a program diskette is
inserted in the disk drive and measurement data
have to be written.
Remedy:
Insert the correct diskette, or a blank one.
CONFIG. DISKETTE
This message appears when a configuration dis-
kette is inserted in the disk drive and measure-
ment data have to be written.
Remedy:
Insert the correct diskette, or a blank one.
Summary of Contents for LOGOSCREEN 500
Page 1: ...Paperless recorder B 95 5015 Operating Instructions 04 02 00378469...
Page 2: ......
Page 6: ...Contents...
Page 48: ...3 Operation and visualization 46...
Page 66: ...4 Configuration parameters 64...
Page 76: ...5 Setup program 74...
Page 87: ...85 10 T V Report on Data Manipulation Security...
Page 88: ...10 T V Report on Data Manipulation Security 86...
Page 89: ...87 10 T V Report on Data Manipulation Security...
Page 90: ...10 T V Report on Data Manipulation Security 88...
Page 97: ......
Page 98: ......
Page 99: ......