15
3 Sensor data
Registry adresses
Sensor specification
Manufacturing data
Registry
Description
0x49
Measuring range start
[15] - Unit: 1 = bar, 0 = mbar
[14] - Prefix sign: 1 = negative, 0 = positive
[13:0] - Value: 0 to 16383
0x4A
Measuring range end
[15] - Unit: 1 = bar, 0 = mbar
[14] - Prefix sign: 1 = negative, 0 = positive
[13:0] - Value: 0 to 16383
0x4B
Sensor type
[15:1] - free
[0] - Type: 1 = absloute pressure, 0 = relative pressure
Registry
Description
0x3E
Part number highword [31:16]
0x3F
Part number lowword [15:0]
0x40
FA number (production order number) highword [31:16]
0x41
FA number (production order number) lowword [15:0]
0x42
Production location – 010 (dec) for JUMO Fulda
0x43
Production date – year [15:8] / calendar week [7:0]
0x44
Counter number (serial number) 000 to 999
0x45
T
offset
(value range floating point value from 0 to -1024)
Value 0 = 0
Value 65535 = -1024
0x45
T
slope
(value range floating point value from 0 to 0.05)
Value 0 = 0
Value 65535 = 0.05
Offset =
-T
* 1024
offset
65535
Slope =
T
* 0.05
slope
65535