ENGLISH
46
TROUBLESHOOTING
Before use
Problem Possible
cause
Solution
No gas flow through the
metering valve.
The metering valve is not
installed correctly.
Fit the metering valve correctly or
replace the valve and/or the gas
cartridge.
The metering valve is not in
contact with the gas
cartridge.
The metering valve is not
installed correctly.
Fit the metering valve correctly or
replace the valve and/or the gas
cartridge.
The charge indicator light
does not come on when the
cord is plugged in.
The cord has not been plugged
in properly or the power socket
is not working.
Plug the cord in properly or use
another power socket.
The indicator light is broken.
Replace the charger.
The indicator light is on but
the charger does not work.
Poor electrical contact between
the battery and the charger.
Clean the charger terminals using
sandpaper, if necessary. Have the
charger repaired or replaced.
During operation
Problem
Possible cause
Solution
The fasteners do not fit into the magazine.
Wrong
type
of
fasteners.
Use the recommended
fasteners.
The tool can be fired but no fastener comes out.
The fastener is the
wrong angle.
Use the recommended
fasteners.
The feeder does
not push the
fasteners.
Pull out and release the
feeder.
The blue indicator light is on. The work contact
element can be pressed in and the fan rotates, but
when the trigger is squeezed, the ignition works
without combustion.
No gas in the
combustion
chamber.
Replace the gas
cartridge.
Empty gas
cartridge.
Replace the gas
cartridge.
Carbon on the
spark plug.
Clean the spark plug.
No
spark.
Send to authorised
service centre.
The blue indicator light is on. The work contact
element in the nose of the tool can be pushed in but
the fan does not rotate.
Motor is faulty.
Send
to
authorised
service centre.
Electrical
fault.
Send to authorised
service centre.
The trigger does
not work.
Send to authorised
service centre.
The power of the tool is weaker or the piston is not
able to fully return to top.
Dirt on the piston
rings and inner
cylinder surface.
Check and clean the
piston rings and the inner
cylinder surface.
The non-return
valve does not
close fully.
Check and clean the
non-return valve.
The piston ring
vents are together.
Rotate the piston rings
so that the vents face in
opposite directions.
The blue and the red indicator light flashes alternately
for 20 seconds. The tool can still be used. The red
indicator light comes on after 20 seconds and the tool
does not work. Problem not solved by changing
battery.
Electrical fault in
temperature
sensor.
Send to authorised
service centre.
More than one ignition when the trigger is squeezed.
Ground
wire
is
loose or broken.
Send to authorised
service centre.
The tool can only be fired once after the battery has
been changed. Problem not solved by changing
battery.
The contact spring
does not return.
Send to authorised
service centre.