SAFETY INSTRUCTIONS
Read the Operating Instructions carefully before use!
Read these Operating Instructions carefully before use.
The equipment may only be used by adults of sound judgement.
Do not immerse the machine in liquid.
The machine must only be used for the purpose for which it is intended.
Never move the machine while in operation.
The machine must never be used if it is damaged.
Do not allow children to play with the machine.
The machine must not be used in areas where flammable liquids are stored or where flammable
fumes/gases can occur.
Store the machine in a dry place when not in use.
Do not allow water to remain in the tank when the machine is not in use. This will damage the
grinding wheel.
The machine must not be exposed to chemicals.
The machine must be placed on a flat and stable surface.
Before each use, check that the power cord is not damaged. Do not use the machine if the cord is
damaged.
The power cord must only be replaced by the supplier.
Always wear safety goggles while working with the machine.
Wear ear protection during use.
Never grind articles containing asbestos.
Always keep the work area free from foreign objects and debris.
Never touch the rotating grinding wheel.
A damaged grinding wheel must be replaced immediately.
If the grinding wheel is out of balance or does not rotate evenly, it must be replaced immediately.
Never grind thin sheets such as razor blades, etc. These are too weak and may cause injury.
Never use the machine without guards.
Use only original spare parts and accessories from Jula.
The equipment may only be used by adults of sound judgement.
When the machine needs to be replaced following many years of service, or it is no longer needed,
it must be disposed of according to local regulations.
TECHNICAL DATA
Voltage
230 VAC, 50 Hz
Output power
45 W
Duty cycle
S2, 15 minutes
Motor speed
2,850 rpm
Speed, grinding wheel
250 rpm
Grinding wheel, dim
100 x 20 x 16 mm
Safety class
II, IP23
Weight 1.8
kg
Sound power level, LwA
80,2 dB(A)
Sound pressure level, LpA
67,2 dB (A), K= 3dB
Vibration level
0,188 m/s
2
Always use hearing protection!
The declared vibration value, which has been measured by a standardised test method, can be used to
compare different tools with each other and for a preliminary assessment of exposure.
WARNING!
The actual vibration level when using power tools may differ from the specified maximum
value, depending on how the tool is used. It is therefore necessary to determine which safety precautions
are required to protect the user, based on an estimate of exposure in actual operating conditions (taking
into account all stages of the work cycle, e.g. the time when the tool is switched off and when it is idling,
in addition to the start-up time).