38
−
13. CHANGE-OVER OF THE POWER SOURCE VOLTAGE
This sewing machine has been connected to the power source of 200V to 240V in the state of delivery from the
factory.
When using the machine with the power source of 100V to 120V, perform the work of change-over of voltage in
the order of the procedures below.
1) Remove the cover in the rear of the sewing machine and replace from 200V to 100V the connector of
connector No. CN32 (blue 2-pin) on the right side PWR circuit board as observed from the front side.
See the figure below.
2) Install the cover.
3) Connect the power plug to the receptacle.
4) Completion of the work.
(Caution) 1. Perform the change-over after confirming the voltage of the place where the sewing machine
is set and the voltage in the sewing machine.
2. Do not connect the power plug to the receptacle.
CN32 connector section