– 58 –
Indication
Level
Functions
Setting range
State when
delivered
Remarks
S Jump feed speed of XY
(Setting possible in the unit of
10 pps)
100 to 4000 pps
2000
S XY feed forward / back speed
(Setting possible in the unit of
10 pps)
100 to 4000 pps
500
S When the power supply is
turned on, automatic preparation
is possible without pressing the
READY key.
0 : Normal
1 : Automatic preparation is oper-
ated when the power supply is
ON.
0
S While the needle stays in an
upper position, a current is
maintained in the main motor to
make the needle hard to down.
0 : Holding disabled
1 : Holding enabled
0
U Method of XY enlargement/re-
duction scale rate setting (IP200
only)
0 : % setting
1 : Size setting
0
Displayed only for the IP200 operation
panel.
U The origin is moved toward the
front by 5 mm.
0 : Standard
1 : 5 mm closer to the front
0
This setting is needed when using the
LK1904 presser foot and patterns.
S No. of pulses for work clamp
foot interlock wiper operation
30 to 60
45
S At preparatory state, time to
output thread tension can be set
up at the time of thread tension
setting.
0 to 20
20
S The head falling detector switch
can be disabled.
0 : Normal
1 : Head falling detector switch
disabled
0
U This function sets whether or not
the calling of the pattern data is
operative.
0 : Calling inoperative
1 : Calling operative
Setting de-
pends on
the model
used.
Standard pattern Nos. 1 to 64 can be
individually set. (Standard operation
panel)
S
Initialization of model's specifi
-
cations is executed.
0 : LK1900ANSS
1 : LK1900ANHS
2 : LK1900ANFS
3 : LK1900ANMS
4 : LK1901ANSS
5 : LK1902ANSS
6 : LK1902ANHS
7 : LK1903ANSS-301
8 : LK1903ANSS-302
9 : LK1903ANSS-311/BR35
10 : LK1903ANSS-312/BR35
11 : LK1900ANWS
Setting
values are
specified
at left ac-
cording to
models.
Contents of the memory switches are
initialized to the state when delivered.
The thread tension of each standard
pattern is initialized to the state when
delivered.
All the registrations patterns and cycles
are deleted.
U Grease-up error
The number of stitches is counted
based on drive, sewing machine.
Only clearing possible with the RESET
key.
Clearing should be done after the
completion of grease-up action.
U Pattern registration is carried
out.
U Cycle sewing registration is car-
ried out.
S Test mode is assumed.
Summary of Contents for LK-1900AN
Page 30: ... 18 11 Hook adjustment Standard adjustment For DP 17 For DP 5 0 05 to 0 1 mm ...
Page 100: ... 88 8 Needle thread clamp mechanism area Grease Grease Grease Grease Grease ...
Page 101: ... 89 9 LK 1901AN relations Grease Grease Grease Grease Grease Grease Grease Grease ...
Page 102: ... 90 10 LK 1903AN relations Grease Grease Grease ...
Page 129: ... 117 12 Circuit diagrams 1 Block diagram A ...
Page 130: ... 118 2 Power supply circuit diagram A ...
Page 131: ... 119 3 Power supply circuit diagram B ...
Page 132: ... 120 4 Power supply circuit diagram C ...
Page 133: ... 121 5 Servo motor circuit diagram ...
Page 135: ... 123 7 MAIN PANEL board circuit diagram ...
Page 139: ......