– 47 –
Procedures of assembling and adjustment procedures
1. Push the needle thread clamp device
3
in the direction of A and fix it with the four set screws
2
.
Tighten the hinge screw
1
.
2. Turn on the power supply and press the
key twice so that the needle thread clamp support
plate complete
4
is positioned at the far advanced end.
Confirm that the distance between the needle thread clamp support plate complete
4
and the needle
5
is 3.3 to 3.7 mm and 1.7 to 2.3 mm, respectively.
3. If the distance seems to be inadequate, loosen the four set screws
2
and move the needle thread
clamp device
3
for adjustment.
(Caution) For the prevention of injury, the distance should be checked only if the sewing LED is
unlit. (Press the
key twice after the power supply has been turned on.)
4. After the completion of the above-mentioned reassembly, make adjustments according to "(37) Ad-
justing the needle thread clamp sensor."
1.7 to 2.3 mm
3.3 to 3.7 mm
Summary of Contents for LK-1900AN
Page 30: ... 18 11 Hook adjustment Standard adjustment For DP 17 For DP 5 0 05 to 0 1 mm ...
Page 100: ... 88 8 Needle thread clamp mechanism area Grease Grease Grease Grease Grease ...
Page 101: ... 89 9 LK 1901AN relations Grease Grease Grease Grease Grease Grease Grease Grease ...
Page 102: ... 90 10 LK 1903AN relations Grease Grease Grease ...
Page 129: ... 117 12 Circuit diagrams 1 Block diagram A ...
Page 130: ... 118 2 Power supply circuit diagram A ...
Page 131: ... 119 3 Power supply circuit diagram B ...
Page 132: ... 120 4 Power supply circuit diagram C ...
Page 133: ... 121 5 Servo motor circuit diagram ...
Page 135: ... 123 7 MAIN PANEL board circuit diagram ...
Page 139: ......