4-5. List of memory switch data
No.
Item
Setting range
Unit
U001
Soft-start function
The initial value differs with the machine head. (0: OFF)
0 to 9
Stitch
U002
Material edge sensor function
0:Without the material edge detection function / 1:Sewing machine stops
after sewing the preset number of stitches (U004) following the detection of
material edge
0 to 1
ー
U003
Thread trimming function activated by material edge sensor
0:Without the automatic thread trimming function after detection of material
edge / 1:Sewing machine stops and simultaneously carries out automatic
thread trimming after sewing the preset number of stitches (U004) following
the detection of material edge
0 to 1
ー
U004
Number of stitches for material edge sensor
Number of stitches to be sewn after the detection of material edge until the
sewing machine stops.
0 to 19
Stitch
U007
Bobbin thread count-down unit
0: 10 stitches / 1: 15 stitches / 2: 20 stitches
0 to 2
ー
U008
Reverse feed stitching speed
The initial value differs with the machine head.
The number of revolutions set with this memory switch is given precedence
even if it is lower than the lowest speed by pedal.
150 to 3000
sti/min
U013
Bobbin thread count stop function
0: Sewing machine start prohibition function is disabled even when the
counter completes counting (negative value).
1: When the counter completes counting, the sewing machine start after
thread trimming is prohibited.
2: When the counter completes counting, the sewing machine temporarily
stops and the start of sewing machine after thread trimming is prohibited.
* Note that the prohibition function is disabled in the case the initial value of
counter is 0 (zero).
0 to 2
ー
U014
Sewing count function
1: Automatic sewing counter / 2: Sewing counter switch input
1 to 2
ー
U021
Presser foot lift when the pedal is in its neutral position
0: Disabled / 1: Enabled
0 to 1
ー
U025
Operation after manual turning (thread trimming)
This memory switch is used for setting the thread trimmer operation after the
sewing machine has moved from its upper/lower stop position by manual
turning of handwheel.
0: Permitted / 1: Prohibited
0 to 1
ー
U030
Middle-of-sewing reverse feed stitching function
Midpoint-of-sewing reverse feed stitching function is set.
0: Without the midpoint-of-sewing reverse feed stitching function / 1: With
the midpoint-of-sewing reverse feed stitching function
0 to 1
ー
U031
Number of stitches of middle-of-sewing reverse feed stitching
Number of midpoint-of-sewing reverse feed stitches is set.
1 to 19
Stitch
U032
Condition of enabling middle-of-sewing reverse feed stitching while
sewing machine is at rest
Midpoint-of-sewing reverse feed stitching function enable condition
0: Disabled when the swing machine is at rest / 1: Enabled when the sewing
machine is at rest
0 to 1
ー
– 62 –