– 72 –
No.
Name
Selection item
Setting
range
Unit &
Meaning
Initial value
SS 2516 HS 2516 SL 2615 HL 2516 HS 3020
SL
2516 FU
HL
2516 FU
U082 Opening / closing of the feeding frame
control during temporary stop
0 to 99
1
0
U084 With / without the latch for pedal
switch 1
0: Without
1: With
0 to 1
-
1
U085 With / without the latch for pedal
switch 2
0: Without
1: With
0 to 1
-
1
U086 With / without the latch for pedal
switch 3
0: Without
1: With
0 to 1
-
1
U087 With / without the latch for pedal
switch 4
0: Without
1: With
0 to 1
-
1
U088 Enlargement / reduction function
mode
0: Prohibited
1: Increase / decrease of the number
of stitches (pitch is fixed)
2: Increase / decrease of pitch (the
number of stitches is fixed)
0 to 2
-
1
U089 Inching travel function mode
0: Prohibited
1: Parallel travel
2: Travel to the retrofitted 2nd origin
0 to 2
-
2
U094
Selection of upper dead point of
needle during origin-retrieval / re-
turn-to-origin
0: Without
1: With
0 to 1
-
0
U097 Temporary stop / thread trimming
operation
0: Automatic thread trimming
1: Manual (thread trimming is carried
out by pressing the stop switch
again)
2: Manual (operation on the panel
only)
0 to 2
-
1
U101 Main motor XY feed synchronous
control speed / pitch
0: 2800sti/min /3.5mm
1: 2200sti/min /3.5mm
2: 1800sti/min /3.5mm
3: 1300sti/min /3.5mm
0 to 3
-
0