– 36 –
Item
Input range
Initial value
❶
Two-step stroke
10 to 300(msec)
70(msec)
❷
Thread tension reference value
0 to 200
Set value for pattern
❸
Travel amount in X direction
0.00(mm)
❹
Travel amount in Y direction
0.00(mm)
❺
XY enlargement/reduction ratio
1.00 to 400.00(%)
100.00(%)
❻
Max. speed limitation
200 to 2800(sti/min)
2800(sti/min)
❼
Reference value for the intermediate presser height
0.0 to 3.5(mm)
(Max. 0.0 to 7.0(mm))
Set value for pattern
❽
Current value of the sewing counter
0 to 9999
Hide
❾
Current value of the number of pieces counter
0 to 9999
Hide
Current value of the bobbin thread counter
0 to 9999
Hide
Parameters that can be changed are as described below.
* Initial value of the reference value for thread tension and that of the intermediate presser height
vary with the pattern to be selected.
* The XY enlargement/reduction ratio can be changed to the actual dimension input by changing the
setting of memory switch U064.
* The XY enlargement/reduction ratio input method can be selected with the memory switch U088,
either "increase/decrease of the number of stitches" or "increase/decrease of stitch pitch". It should
be noted, however, that the pattern consists of point sewing elements, the pattern is always en-
larged/reduced by the method of "increase/decrease of stitch pitch" regardless of the setting of the
memory switch U088.
* The maximum value of input range and the initial value of the maximum speed limitation are deter-
mined by the setting of the memory switch U001.
1. In the case the computation cannot be carried out due to excessively small reduc-
tion ratio, "E045: Pattern data error" will be displayed.
2. If the enlargement/reduction ratio is changed using the "increase/decrease of the
number of stitches (with the stitch pitch fixed)" method, mechanical control com
-
mand(s) entered other than shape point(s) will be deleted.
* The current value of counters are not displayed in the case the counters are set to "Not use".
* The reference value of the intermediate presser height cannot be changed immediately after turn-
ing the power ON. Press READY button
to retrieve the origin, first. Then, change the refer
-
ence value of the intermediate presser height.