(15) Hook adjustment
When a DP x 5
needle is used
DP x 17 needle
(of which needle
count is lower
than #22) is used.
: Marker line for DP x 5 needle
: Marker line for DP x 17 needle
(with needle count higher than #22)
: Marker line for DP x 17 needle
(with needle count lower than #22)
– 27 –
DP x 17 needle
(of which needle
count is higher
than #22) is used.
0mm
0mm
Standard Adjustment
0.05 to 0.1mm
7.5mm
b
A
0.5mm
D
C