RS232 CONTROL AND MONITORING
To operate the iP1520 using RS232 you will need a suitable cable from the PC
to the iP1520 RJ11 RS232 port on the rear of the unit. Below is the pin out for a
RJ11 to female DB9 cable. This cable will need to be constructed or pur-
chased.
RS232 CABLE PINOUT
RS232 COMMANDS
Using Terminal Software such as Windows Hyper Terminal or Micro Terminal
which you can download from our website at http://juicegoose.com/product-ip-
1520.html
, the following commands can be issued to the iP1520.
NOTE: A DEACTIVATE command must be issued first to ensure the physical
sequence up/down switch position does not override the RS232 commands.
ACTIVATE - Enables the sequence up/down switch on the front of the
iP1520
DECACTIVATE - Disables the sequence up/down switch on the front of
the iP1520
POD1ON – Turns POD 1 on
POD1OFF – Turns POD 1 off
POD2ON – Turns POD 2 on
POD2OFF – Turns POD 2 off
POD3ON - Turns POD 3 on
POD3OFF – Turns POD 3 off